2-4. E: 18.X. External communication error (Indoor unit)
Indoor unit
Indicator
outdoor unit
Detective actuator
Indoor unit
Forecast of cause
Check point 1. Check the connection
Check any loose or removed connection between the main PCB to the →AN adapter.
-> If there is an abnormal condition, correct it by refer to the installation manual or the "DESIGN
& TECHNICAL MANUAL".
Check the connection condition on the →LAN adapter and the main PCB (If there is loose con-
nector, open cable or mis-wiring.)
Check point 2. Replace the →LAN adapter
If check point 1 do not improve the symptom, change →LAN adapter.
Check point 3. Replace main PCB
If check point 2 do not improve the symptom, change main PCB
2-4. E: 18.↓. External communication error (Indoor unit)
Operation indicator
Timer indicator
Economy indicator
Error code
External
communication
error
End
Continuous flash
Refer to
"Error code table (Outdoor unit)"
After receiving a signal from the external input and
output PCB, the same signal has not been received for
15 seconds.
Connection failure
→LAN adapter failure
- (03-18) -
1 time flash
8 time flash
E: 18
on page 03-4
Main PCB
2. Troubleshooting with error code