Single/three phase wireless mobile water level controller

Advertisement

MISSED CALL FOR ON/OFF CONTROL
S.No
COMMAND
1
Call cuts off after Long ring (>4)
2
Call cuts off after Short ring (>2)
Starter Connection Diagram:
Blue pair wire
Start button
Installation steps of GSM Controller:
Caution: Switch off the main power while doing the Power Connection steps.
 Step 1: Insert your GSM SIM in the SIM slot given as shown in the GSM controller.
 Step 2: Wall mount the GSM controller by using the screws in the given slots on its sides.
 Step 3: Remove the 'R' wire from starter & insert into the CT coil, and connect it back to the
starter.
 Step 4: Connect L1, L2, L3 to R, Y, B input line of the starter respectively.
 Step 5: In your starter, Connect Blue pair wire of the controller to the start button in parallel as
shown in the Picture 1.
 Step 6: Trace the wire that connects the start and stop button terminals. Remove this wire
from the stop button and join it with the any one black wire of Relay Black Pair.
 Step 7: Connect the Left out black wire of Relay Black Pair to the stop button where the wire
was removed as shown in the Picture 1.
 Step 8: Connect the GSM antenna in the slot provided on the left side of the controller.
 Step 9: Connect the sensor output to the water float switch through 4 pair communication
cable.
If the starter is not matching with the above suggested connection kindly What's app us on
9940594413 or call 044-43180017 for support!!!!!
Share the starter photo front panel and opened panel photo in what's app.
 Step 7: Verify all the connections and then Switch ON the controller.
Web: www.rmgautomation.com
DESCRIPTION
MOTOR ON
MOTOR OFF
CT COIL
Black pair wire
Stop button
CONTACTOR
Picture 1.
eMail: rmgworld@hotmail.com
GSM1SPAT - Installation Manual
MOTOR ON/OFF COMMAND
S.No
COMMAND SMS
1
2
Y
B
R
STARTER
Mobile: +91 99405 94413
MESSAGE
DESCRIPTION
11
MOTOR ON
10
MOTOR OFF
2