Bryant DELUXE 355AAV Product Data
Bryant DELUXE 355AAV Product Data

Bryant DELUXE 355AAV Product Data

High efficiency gas furnace deluxe 4-way multipoise variable-speed two-stage condensing gas furnace series 120 input rates: 40,000 thru 120,000 btuh

Advertisement

355AAV EVOLUTIONtHIGH EFFICIENCY GAS FURNACE
DELUXE 4- - WAY MULTIPOISE VARIABLE- - SPEED
TWO- -STAGE CONDENSING GAS FURNACE
Series 120 Input Rates: 40,000 thru 120,000 Btuh

Product Data

Perfect Heatt technology, the ultimate in heating
comfort . . .
The Bryant Evolutiont with Perfect Heatt technology achieves
the optimum combination of comfort and efficency.
The Evolutiont achieves industry- -leading ultra- -high efficiency at
up to 96.6 percent Annual Fuel Utilization Efficiency (AFUE).
Efficient performance is enhanced through the variable- -speed
design. To maintain ideal comfort, Perfect Heatt
automatically adjusts the heating level, maximizing the use of low
heating levels that produce near silent furnace operation while
meeting the exact heating needs. This unit is designed to keep the
indoor temperature within less than 1 degree of the thermostat
setpoint. Because it operates in low heat most of the time, the
Evolutiont uses up to 80% less power than single- -capacity
furnaces.
In addition to providing ultimate comfort, the Evolutiont has a
sealed combustion system. This system brings combustion air to
the furnace and vents flue gases outside the furnace in a safe
manner. Because it is sealed, operational noise is minimal. A sealed
combustion system also means fewer cold drafts and less air
infiltration.
Quality materials are the key behind the Evolution'st outstanding
performance. Bryant stands behind quality. We offer lifetime
warranty protection* on the heat exchangers, the heart of the
Evolutiont . The rest of the furnace is backed by a limited 5- -year
warranty.
A08030
The Evolutiont is available in 6 heat/airflow combinations. The
unit has a 4- -way multipoise design and can be installed in upflow,
downflow, or horizontal positions covering up to 24 different
applications. The Evolutiont can be vented as a
vent/2- -pipe furnace or as a non- -direct vent/1- -pipe application.
The versatile 4- -way multipoise design in conjunction with variable
speed makes the Evolutiont ideal for use with split system
cooling, including 2- -speed units. A Bryant Evolutiont air
purifier, humidifier, comfort ventilator, and Comfort Zone II
control will provide year round comfort and efficiency.
Designed for durability, comfort, and reliability, the Evolutiont is
the ultimate in versatile, efficient comfort.
Bryant
variable- -speed gas furnace is matched with the Evolutiont
Control and an air conditioner or heat pump, the homeowner will
experience the ultimate in Perfect Heatt and Perfect Humidityt
through unparalleled control of temperature, humidity, indoor air
quality, and zoning. The Bryant Evolutiont System also provides
unprecedented ease of use through onscreen, text- -based service
reminders and equipment malfunction alerts.
1
Evolutionr
System
technology
Direct
When
the
Evolutiont

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DELUXE 355AAV and is the answer not in the manual?

Questions and answers

Summary of Contents for Bryant DELUXE 355AAV

  • Page 1 The versatile 4- -way multipoise design in conjunction with variable speed makes the Evolutiont ideal for use with split system cooling, including 2- -speed units. A Bryant Evolutiont air purifier, humidifier, comfort ventilator, and Comfort Zone II control will provide year round comfort and efficiency.
  • Page 2 When installed as a part of the system, this propane gases. The furnace is factory- -shipped for use with natural cabinet allows for easy and convenient addition of a Bryant high gas. A CSA listed gas conversion kit is required to convert furnace efficiency air filter.
  • Page 3: Furnace Components

    FURNACE COMPONENTS A02287 NOTE: a. The 355AAV Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory- -authorized and listed accessory conversion kit. b. Control location and actual controls may be different than shown above. 1.
  • Page 4 BRYANT ACCESSORIES UNIT SIZE DESCRIPTION PART NO. 042040 042060 042080 060080 060100 060120 2---in. — KGAVT0101BRA Vent Termination Kit (Bracket Only for 2 Pipes) 3---in. — KGAVT0201BRA 2---in. — KGAVT0501CVT Concentric Termination Kit (Single Exit) 3---in. — KGAVT0601CVT Condensate Freeze Protection Kit...
  • Page 5 BRYANT ACCESSORIES (CONTINUED) UNIT SIZE DESCRIPTION PART NO. 042040 042060 042080 060080 060100 060120 Natural---To---Propane Gas Conversion Kit KGANP4101ALL (Single Kit)* Propane---To---Natural Gas Conversion Kit KGAPN3501ALL (Single Kit) ECM Motor Simulator (replaces the ECM motor KGASD0301FMS to aid troubleshooting Door Gasket Kit...
  • Page 6 THERMOSTAT AND ZONING CONTROL OPTIONS NON---PROGRAMMABLE THERMOSTAT SELECTION For use with 1 speed Air Conditioner --- _F/_C, Auto Changeover TC ---NAC or TP ---NAC TC ---NHC or TP ---NHC For use with 1 speed Air Conditioner --- _F/_C, Auto Changeover TP ---NRH* For use with 2 speed Air Conditioner --- _F/_C, Auto Changeover * Model HP &...
  • Page 7 One pipe used or when a coil box other than a Bryant cased coil is used. It is runs inside the other allowing venting through the inner pipe and A.G.A.
  • Page 8 C E RTI FI E D REGISTERED QUALITY SYSTEM MEETS DOE RESIDENTIAL As an ENERGY STAR CONSERVATION SERVICES Partner, Bryant Corporation These products are engineered and PROGRAM STANDARDS. has determined that this manufactured under an ISO 9001 registered Before purchasing this product meets the ENERGY quality system.
  • Page 9: Physical Data

    PHYSICAL DATA UNIT SIZE DESCRIPTION 042040 042060 042080 060080 060100 060120 Direct--- Drive Motor Hp (ECM) Motor Full Load Amps 12.8 12.8 12.8 RPM (Nominal)—Speeds Variable 250 — 1300 Blower Wheel Diameter X Width (in.) 11 X 10 10 X 7 11 X 10 11 X 10 11 X 10...
  • Page 10 AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) External External Static Pressure (ESP) Static Unit Operating Mode Airflow Pressure Size Setting Range* 042040 †† Low Heat 540† 0 ---0.50 High Heat 785† 0 ---1.0 †† 1 ---1/2 ---Ton A/C Cooling 0 ---0.50‡...
  • Page 11 FIELD-SUPPLIED 2-IN. DIAMETER FIELD-SUPPLIED PVC 90° ELBOW 2-IN. DIAMETER PVC PIPE COMBUSTION-AIR DISC (FACTORY-SUPPLIED IN LOOSE PARTS BAG) A96211 Length of Straight Pipe Portion of Combustion Air Inlet Pipe Assembly (In / mm) CASING WIDTH 17 1/2 / 444.5 8 1/2+/--- 1/2 / 215.9 +/--- 12.7 21 / 533.4 10 1/2 +/--- 1/2 / 266.7 +/--- 12.7 24 1/2 / 622.3...
  • Page 12: Condensate Trap

    FURNACE BLOWER SHELF CONDENSATE DOOR TRAP FURNACE CONDENSATE DOOR FURNACE TRAP (INSIDE) FURNACE SIDE SIDE FIELD FIELD DRAIN DRAIN ALTERNATE DRAIN CONN CONN TUBE LOCATION SIDE VIEW FRONT VIEW END VIEW FRONT VIEW CONDENSATE TRAP DRAIN TUBE LOCATION DOWNFLOW AND ALTERNATE HORIZONTAL UPFLOW APPLICATIONS APPLICATIONS...
  • Page 14 DIMENSIONS (IN. / MM) HOLE NO. FOR PLENUM OPENING* FLOOR OPENING FURNACE FURNACE IN DOWNFLOW WIDTH CASING WIDTH APPLICATION ADJUSTMENT Furnace with or without Cased Coil 15--- 1/8 / 16--- 3/4 / 20--- 3/8 / 17--- 1/2 / 444.5 19 / 482.6 Assembly or Coil Box 384.2 425.5...
  • Page 15: Electrical Data

    ELECTRICAL DATA UNIT SIZE 042040 042060 042080 060080 060100 060120 UNIT VOLTS --- HERTZ --- PHASE 115 --- 60 --- 1 OPERATING VOLTAGE RANGE 104 --- 127 (Min --- Max)* MAXIMUM UNIT AMPS 13.8 13.8 13.8 MINIMUM WIRE SIZE MAXIMUM WIRE LENGTH (Ft / M)‡ 31 / 9.4 31 / 9.4 31 / 9.4...
  • Page 16 COMBUSTION- - AIR AND VENT PIPING FOR DIRECT VENT/2- - PIPE (ALL SIZES) AND NON- -DIRECT VENT/1- - PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS Maximum Allowable Pipe Length (Ft / M) VARIABLE SPEED VENT SIZING TABLE NUMBER OF 90_ ELBOWS Direct &...
  • Page 17 COMBUSTION- - AIR AND VENT PIPING FOR DIRECT VENT/2- - PIPE (ALL SIZES) AND NON- -DIRECT VENT/1- - PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS Maximum Allowable Pipe Length (Ft / M) (Continued) Variable Speed Vent Sizing Table NUMBER OF 90_ ELBOWS Direct &...
  • Page 18 MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT / M) WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* INSULATION THICKNESS† WINTER DESIGN WINTER DESIGN MAXIMUM PIPE MAXIMUM PIPE UNIT SIZE TEMPERATURE DIAMETER (IN.) 20_F / --- 6.7_C 21 / 6.4 37 / 11.3 42 / 12.8 50 / 15.2 57 / 17.4...
  • Page 19: Clearance To Combustibles

    INSTALLATION This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size furnaces are only approved for altitudes 0 - 7,000 ft. (0 - 2,135m). An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications. This furnace is for indoor installation in a building constructed on site.
  • Page 20 COMBUSTION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) OUTDOOR UNIT VENT PIPE A/C COIL HUMIDIFIER COMBUSTION AIR INLET (NON-DIRECT 1-PIPE APPLICATION) GAS-FIRED WATER HEATER ELECTRONIC AIR CLEANER FRONT OF AIRFLOW FURNACE A05064 Upflow Application ELECTRONIC AIR CLEANER VENT COMBUSTION AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION COMBUSTION AIR (DIRECT VENT/...
  • Page 21 COMBUSTION-AIR INLET (NON-DIRECT VENT/1-PIPE APPLICATION) COMBUSTION–AIR PIPE VENT PIPE DIRECT VENT/2-PIPE APPLICATION) ELECTRONIC AIR CLEANER FRONT OF FURNACE FURNACE CONDENSATE DRAIN AIR CONDITIONING COIL REFRIGERATION PIPING AIRFLOW A05066 Attic --- Horizontal Application COMBUSTION– AIR PIPE COMBUSTION - AIR INLET (DIRECT VENT/2-PIPE (NON-DIRECT VENT/ APPLICATION) 1-PIPE APPLICATION)
  • Page 22 Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements. Catalog No. PDS355A.40.2 E2008 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 01/08 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

This manual is also suitable for:

355aav evolution

Table of Contents

Save PDF