PLUS 95s
MODEL 355CAV
t
DELUXE 4- -WAY MULTIPOISE VARIABLE- - SPEED
MULTI- - STAGE CONDENSING GAS FURNACE
Series 100 Input Rates: 60,000 thru 120,000 Btuh
Product Data
Building on our industry- -leading family of condensing furnaces,
the Plus 95st, model 355CAV with the consistent comfort that is
provided by Bryant's PerfectSenset feature is our greatest
advancement to date.
In fact, temperature and humidity control, operating efficiency,
installation flexibility (and simplicity), and quiet operation are all
evidence of Bryant's ingenuity.
The PerfectSense feature provides up to 73% more consistent
temperature control than single stage furnaces. This comfort is
achieved through Bryant's modulating operation, and the many
patented features found in our PerfectSense control. This control
senses the heating needs of the home, and interacts with the
mulit- -stage gas valve, a variable- -speed inducer motor, and
variable- -speed blower motor, allowing the Plus 95s to adjust
combustion air, firing rate, and airflow to maintain peak efficiency
and exceptional comfort throughout the operating cycle.
These important components also contribute to exceptionally quiet
operation as well, especially when the Plus 95s operates in it's
lowest stage of heating operation. Inducer motor and blower motor
operation and gas consumption all adjust to their lowest and
quietest levels. This quiet operation can be enjoyed the majority of
the year, as the Plus 95s can operate as frequently as 83% of the
time during heating operation.
The Plus 95s also achieves heating efficiencies of 95 percent
Annual Fuel Utilization Efficiency (AFUE) in the upflow
configuration. The Plus 95s provides the ultimate in electrical
efficiency as well, due to the tried and true patented Everlastict
secondary heat exchanger, and it's industry- -leading low air- -side
pressure drop.
This ultra- -highly efficient 4- -way multipoise gas furnace is not
only flexible in terms of how it can be installed, but is as easy to
install as any Bryant condensing furnace equipped with the
Evolutiont solution, as compared to other, more complicated
modulating furnaces from other manufacturers.
A05085
Bryant Evolution System—When this Plus 95s gas furnace is
matched with the Evolution Control and an air conditioner or heat
pump, homeowners will experience the ultimate in PerfectSense
and Perfect Humidity features through unmatched control of
temperature, humidity, indoor air quality, and zoning. The Bryant
Evolution System also allows for worry- -free operation through
on- -screen,
malfunction alerts.
For even greater comfort and convenience, match the Plus 95s
furnace with a two- -speed Puron air conditioner or heat pump
(Bryant's Hybrid Heatt dual fuel system!) This will create a fully
communicating system, requiring only 4 thermostat wires between
system components, and some troubleshooting can even be done
from the outdoor unit without entering the home. Optional remote
access through telephone or Internet is also available when
combined with a remote connectivity kit.
1
text- -based
service
reminders
and
equipment

Advertisement

Table of Contents
loading

Summary of Contents for Bryant PLUS 95s

  • Page 1 This quiet operation can be enjoyed the majority of the year, as the Plus 95s can operate as frequently as 83% of the time during heating operation. The Plus 95s also achieves heating efficiencies of 95 percent Annual Fuel Utilization Efficiency (AFUE) in the upflow configuration.
  • Page 2 Deluxe furnaces. When installed as a part of the system, this the time in low- -heat and reserves additional firing rates for times cabinet allows for easy and convenient addition of a Bryant high- -- - when the heating demand is higher. The PerfectSense/Perfect efficiency media air filter.
  • Page 3: Furnace Components

    FURNACE COMPONENTS A07609 NOTE: S The 355CAV Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory- -authorized and listed accessory conversion kit. S Control location and actual controls may be different than shown above. 1.
  • Page 4 BRYANT ACCESSORIES UNIT SIZE DESCRIPTION PART NO. 042060 042080 060080 060100 060120 2---in. — KGAVT0101BRA Vent Termination Kit (Bracket Only for 2 Pipes) 3---in. — KGAVT0201BRA 2---in. — KGAVT0701CVT Concentric Termination Kit (Single Exit) 3---in. — KGAVT0801CVT Condensate Freeze Protection Kit...
  • Page 5 BRYANT ACCESSORIES (CONTINUED) UNIT SIZE DESCRIPTION PART NO. 042060 042080 060080 060100 060120 Natural---To---Propane Gas Conversion Kit (Single Kit)* KGANP4301STM Propane---To---Natural Gas Conversion Kit (Single Kit) KGAPN3601STM ECM Motor Simulator (simulates the ECM motor to aid KGASD0301FMS troubleshooting Door Gasket Kit...
  • Page 6 C E RTI FI E D MEETS DOE RESIDENTIAL REGISTERED QUALITY SYSTEM As an ENERGY STAR CONSERVATION SERVICES Partner, Bryant Heating & These products are engineered and PROGRAM STANDARDS. Cooling Systems Corporation manufactured under an ISO 9001 registered Before purchasing this has determined that this quality system.
  • Page 7 Bryant cased coil is used. It is combustion air to be drawn in through the outer pipe.
  • Page 8: Physical Data

    PHYSICAL DATA UNIT SIZE DESCRIPTION 042060 042080 060080 060100 060120 Direct--- Drive Motor Hp (ECM) Motor Full Load Amps 12.8 12.8 12.8 RPM (Nominal)—Speeds Variable 250 — 1300 Blower Wheel Diameter X Width (in.) 10 X 7 11 X 10 11 X 10 11 X 10 11 X 10...
  • Page 9: Operating Mode

    AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) CFM Airflow External Static External Static Pressure (ESP) Operating Mode Unit Size Pressure Setting Range* 042060 410{ Low Heat 0 ---0.50 560{ Medium Heat 0 ---0.50 1070{ 1065 1070 1070 1070 1070 1070 1070 1065 1045 1015 High Heat 0 ---1.0 1 ---1/2 ---Ton A/C Cooling...
  • Page 10 COMBUSTION- -AIR PIPE FOR NON- - DIRECT (1- - PIPE) VENT APPLICATION (SIZES 040 THROUGH 120 ONLY) FIELD-SUPPLIED 2-IN. (51 mm) DIA. FIELD-SUPPLIED PVC 90° ELBOW 2-IN. (51 mm) DIA. PVC PIPE COMBUSTION-AIR DISC (FACTORY-SUPPLIED IN LOOSE PARTS BAG) A96211 Length of Straight Pipe Portion of Combustion Air Inlet Pipe Assembly --- In.
  • Page 11: Condensate Trap

    CONDENSATE TRAP FURNACE BLOWER SHELF CONDENSATE DOOR TRAP FURNACE CONDENSATE DOOR FURNACE TRAP (INSIDE) FURNACE SIDE SIDE FIELD FIELD DRAIN DRAIN CONN CONN ALTERNATE DRAIN TUBE LOCATION SIDE VIEW FRONT VIEW END VIEW FRONT VIEW CONDENSATE TRAP DRAIN TUBE LOCATION HORIZONTAL DOWNFLOW AND ALTERNATE UPFLOW APPLICATIONS...
  • Page 13 DOWNFLOW SUBBASE LOCATING ″ TYP PLENUM OPENING LOCATING FACTORY-SUPPLIED FIELD-INSTALLED INSULATION A97427 A88207 Assembled Disassembled DIMENSIONS (IN. / MM) FURNACE HOLE NO. PLENUM OPENING* FLOOR OPENING FURNACE IN DOWNFLOW CASING FOR WIDTH APPLICATION WIDTH ADJUSTMENT Furnace with or without 15--- 1/8 / 16--- 3/4 / 20--- 3/8 / Cased Coil Assembly or Coil...
  • Page 14: Electrical Data

    ELECTRICAL DATA UNIT SIZE 042060 042080 060080 060100 060120 UNIT VOLTS --- HERTZ --- PHASE 115 --- 60 --- 1 OPERATING VOLTAGE RANGE (Min --- Max)* 104 --- 127 MAXIMUM UNIT AMPS 8.96 8.96 14.06 14.06 14.06 MINIMUM WIRE SIZE MAXIMUM WIRE LENGTH (Ft)‡...
  • Page 15 MAXIMUM ALLOWABLE PIPE LENGTH (FT / M) Direct Vent (2 ---Pipe Only) NUMBER OF 90_ ELBOWS UNIT SIZE Termination Pipe Dia ALTITUDE (BTUH) Type (IN.)* 2 Pipe or 2--- In. 1--- 1/2 50 / 15.2 45 / 13.7 40 / 12.9 35 / 10.7 30 / 9.1 25 / 7.6...
  • Page 16 MAXIMUM ALLOWABLE PIPE LENGTH (FT / M) (CONTINUED) Direct Vent (2- -Pipe Only) NUMBER OF 90_ ELBOWS UNIT SIZE ALTITUDE Termination Pipe Dia (BTUH) Type (IN.)* 2 Pipe or 2--- In. 1--- 1/2 35 / 10.7 30 / 9.1 25 / 7.6 20 / 6.1 15 / 4.6 10 / 3.0...
  • Page 17: Clearance To Combustibles

    CLEARANCE TO COMBUSTIBLES 335122-201 REV. B LIT TOP A08435...
  • Page 18: Typical Installations

    TYPICAL INSTALLATIONS COMBUSTION AIR PIPE OUTDOOR UNIT VENT PIPE A/C COIL HUMIDIFIER GAS-FIRED WATER HEATER ELECTRONIC AIR CLEANER FRONT OF AIRFLOW FURNACE A06511 Upflow Application ELECTRONIC AIR CLEANER VENT COMBUSTION AIR (DIRECT VENT/ HUMIDIFIER 2 PIPE APPLICATION OUTDOOR UNIT A/C COIL AIRFLOW FRONT OF FURNACE...
  • Page 19 TYPICAL INSTALLATIONS (CONTINUED) COMBUSTION–AIR PIPE VENT PIPE DIRECT VENT/2-PIPE APPLICATION) OPTIONAL VENTILATED COMBUSTION AIR APPLICATION ELECTRONIC AIR CLEANER FRONT OF FURNACE FURNACE CONDENSATE DRAIN AIR CONDITIONING COIL REFRIGERATION PIPING AIRFLOW A07800 Attic --- Horizontal Application OPTIONAL VENTILATED COMBUSTION AIR INTAKE COMBUSTION–...
  • Page 20: Guide Specifications

    Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements. Catalog No. PDS355CAV.060.03 E2009 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/09 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

This manual is also suitable for: