Mianyang Weibo Electronic WBP314P75 User Manual

Mianyang Weibo Electronic WBP314P75 User Manual

Active power transducer (3-phase 4-wire)

Advertisement

Quick Links

Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital
WB
WB
WBP314P75
WB
Any quality problem found in WB series products, we offer
Three years free charge of repair the products, and six months guaranteed free charge of change and return the
Electrical Transducer since 1989
USER
USER
MANUAL
MANUAL
USER
USER MANUAL
MANUAL
P314P75
active
power
P314P75 active
P314P75
active power
active
power
power transducer
(3 (3 (3 (3- - - - phase
phase
phase
phase 4 4 4 4 - - - - wire)
www.wb-my.com
wbdz@yahoo.cn
Tel: 86 816 2971265
Fax: 86 816 2281934
ISO9001 ISO14000 ISO18000
Certified
Quality Warranty
products.
transducer
transducer
transducer
wire)
wire)
wire)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WBP314P75 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mianyang Weibo Electronic WBP314P75

  • Page 1 Electrical Transducer since 1989 USER USER MANUAL MANUAL USER USER MANUAL MANUAL P314P75 active power transducer WBP314P75 P314P75 P314P75 active active active power power power transducer transducer transducer (3 (3 (3 (3- - - - phase phase phase phase 4 4 4 4 - - - - wire)
  • Page 2 Application Application Application WBP314P75 adopts special made isolation module, professional MCU controller and the technologies of high speed data synchronizing sampling and processing to isolate and convert active power from three-phase four-wired electric circuit into a load independent output DC average current signal 4-20mA.
  • Page 3 Product Product Terminal Terminal Terminal Terminal Identification Identification Identification Identification Drawing Drawing Drawing Drawing GND1 WBP314P75 Power Source Led Key Technical Technical Technical Technical Data: Data: Data: Data: 1. Input: V: 0~ 10V…0~500V; I: 0~30A; 2. Output: 4mA~20mA 3. Input Frequency: 50 Hz, 60Hz 4.
  • Page 4 8. Over Load Capacity: 2 times of nominal input voltage, continuous; 20 times of nominal input current, continuous. 9. Output impedance: 6V 10. Auxiliary Power: +12Vdc/+24Vdc 11. Current consumption for static status: 12. Isolation Voltage(Input/Output/Power): 1500V , for 1 minute 13.
  • Page 5 Auxiliary power: 24V±1%,ripple≤5mV Ambient temperature: 25℃±2℃ Relative humidity : RH(45~75)% Accuracy for Signal Power Source instrument: 0.05 Auxiliary Power Three 250Ω Phase Power Transducer Source 2(4) (3) Warming up the transducer for 3 minutes (4) Based on the indication of 3-phase AC Calibration Meter, set one set of input value which is within the measuring range of the transducer Ur (line voltage), Ir, COSφ, and the 3-phase input is balanced.
  • Page 6 Don’t dismantle the product, and carry with care to avoiding bump and fall of the product; If the product has been using under the environment with strong magnetic field interference, please pay attention to the shield of input wire, and the output signal wire should be as short as possible.

Table of Contents