SIGNATURE COMMAND SYSTEM OPERATION

FEATURES

Command Center
Easy Access Function Operation and System Con-
figuration
Operation Confirmation/Fault Diagnostic Indications
(LED/Buzzer)
ON/OFF Operation
Optional Wall Mounting
Control Board
Electronic Ignition
Pilot Lockout safety feature
Electric Power Regeneration from Thermopile to save
battery
6-hour Automatic Shut Down Option
Standing Pilot/Intermittent pilot Conversion
Previous settings Restoration Ability (Memory Off)
Uninterrupted Operation During Power Outage (Auto-
matic Battery Backup)
ON/OFF RF Remote Receiver
Optional Transmitter Learn Capability
AC Module (Requires TSFSC Remote)
Easy Snap-on Design
Embedded Compact 120 VAC Adapter with Auto Bat-
tery Back up Feature
Remote Controlled 3-step Blower, Lighting, and On/
Off Auxiliary AC Outputs
Transmitter – TSFSC
Low battery Indication for Transmitter
Child Proof Lock-out
LCD Backlight
Security Codes 16
Countdown 6 hr Timer
Standard Thermostatic Control Mode
Three Brightness Settings for Lights
On/Off Auxiliary

BATTERY INSTALLATION

The Command Center uses four (4) "AA" batteries as
back up for power outages. The system can operate for
approximately six (6) months on battery power.
To Install Batteries (not included):
1. Press down the battery door tabs and pull out to remove
battery door.
Monessen • AVFL42NTSC-SR Installation Instructions • 4116-900 Rev. B • 10/19
RF Receiver
ON/OFF
NG/LP
Conversion
CONTROL BOARD
ON
Master Switch
LED
OFF
Battery Door
Figure 22 –
Signature Command
System Components
®
2. Install the batteries as indicated on Command Center.
3. Close battery door by snapping in place.
4. When the four (4) batteries are installed the system will
operate without power.
FP1917
5. The batteries should be replaced when the LED indi-
Signature components
cates low battery or at least once a year.
8/08

SYSTEM CONFIGURATION/SETUP

All system configuration/setup is done on the Command
Center.
NOTE: When using On/Off wall switch, the switch must be
in the ON position to perform all configuration set ups at
the command center.

COLD CLIMATE OPTION

Choose the Mode That Best Suits Your Needs
The Signature Command
in either Standing Pilot or Intermittent Pilot mode.
The Standing Pilot Mode is best for colder climates
when the pilot must remain on continuously to prevent
condensation and ensure reliable operation.
The Intermittent Pilot Mode is ideal for maximum effi-
ciency, igniting the pilot only when needed to start your
fireplace, lowering fuel consumption and reducing your
carbon footprint.
Either mode benefits from the instantaneous battery back-
up, so you never have to worry about a power outage.
AVFL Vent Free Fireplace
To Thermopile
To Sensor
To Sparker
To Command Center
To Stepper Motor
To Valve
AC Module
COMMAND CENTER
System is designed to operate
®
FP1917