L200Y SLIDING GATE OPERATOR USER'S MANUAL

7. Control

Remote control: The remote control works in a single channel mode. It has four buttons.
See Fig.10 Remote control. The function of button 1, button 2 and button3 are the same.
With each press of the remote control button, which has been programmed, the gate will
close, stop, open or stop cycle. Button 4 is available to set pedestrian mode.
You can program/learn button 1, button 2, button 3 individually. You also can program/learn
two buttons or three buttons together, but you need repeat the program/learn process if you
want to use more than one button.
Adding extra remote controls (Learn): Press the button 'AN' (See Fig.9 terminal 17) on the
control board, then the 'LED2' will be on and turn off, the beeper will ring about 1 second,
then press the remote control button which you want to use, the 'LED2' will turn on and
then turn off again, the beeper will ring about 2 seconds. The learning process is finished.
Up to 100 remote controls may be used.
Erase remote controls: To erase all existing remote controls, press and hold 'AN' button,
the beeper will ring, release the button once the beeper stops ringing. This indicates that
all the remote controls have been erased completely.
NOTE: For safety and security, we recommend that the factory setting be replaced with a
personal code.
Press the 'OPEN' button of external button switch or remote control button which has been
programmed, the gate will open, the motor rotates clockwise, the output voltage between
'D' and 'D' is AC240V, the voltage between 'U' and 'V' is AC240V. Press 'STOP' button or
the same remote control button, the gate stops running. Press 'CLOSE' button or the same
remote control button again, the gate will close, the motor rotates anticlockwise, the output
voltage between 'D' and 'D' is AC240V, the voltage between 'U' and 'W' is AC240V. Press
the 'STOP' button or the same remote control button, the gate stops running.
Verify open direction: If the gate does not move in the desired direction, then you will need
to reverse the motor operating direction, you can do this by exchanging wires 'V' and
'W', 'OP' and 'CL'.