Advertisement

Quick Links

COMPATIBLE CURRENT
n
PROBES & SENSORS FOR
POWER QUALITY METERS
E N G L I S H
User Manual
193-24-BK
193-36-BK
A196-24-BK
MA193-10-BK
MA193-14-BK
MN93-BK
MN193-BK
MR193-BK
SL261-BK
SR193-BK
J93

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A196-24-BK and is the answer not in the manual?

Questions and answers

Summary of Contents for AEMC instruments A196-24-BK

  • Page 1 193-24-BK COMPATIBLE CURRENT 193-36-BK PROBES & SENSORS FOR A196-24-BK POWER QUALITY METERS MA193-10-BK MA193-14-BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK E N G L I S H User Manual...
  • Page 2 Copyright © Chauvin Arnoux , Inc. d.b.a. AEMC Instruments. All rights reserved. ® ® No part of this documentation may be reproduced in any form or by any means (including electronic storage and retrieval or translation into any other language) without prior agreement and written consent from Chauvin Arnoux , Inc., as governed ®...
  • Page 3 Thank you for purchasing an AEMC current probe. For best results from your instrument and for your safety, read the enclosed operating instructions carefully and comply with the precautions for use. These products must be only used by qualified and trained users. WARNING, risk of DANGER! The operator must refer to these instructions whenever this danger symbol appears.
  • Page 4 PRECAUTIONS BEFORE USE The protection assured by the current probe can be compromised if it is used in a way that is not recommended by the manufacturer. ■ Comply with the rated maximum voltage and current, and the measurement category. Do not use the current probe on networks where the voltage or category exceeds those specified.
  • Page 5: Table Of Contents

    Table of Contents 1. INTRODUCTION ..............4 1.1 Receiving Your Shipment..............4 1.2 Ordering Information ................4 2. PRODUCT FEATURES ............5 2.1 Control Features ...................5 2.1.1 AmpFlex Models 193-24-BK, 193-36-BK & 196-24-BK ..5 ® 2.1.2 MiniFlex Model MA193-BK .............6 ® 2.1.3 AC/DC Current Probe Model J93 ..........7 2.1.4 AC Current Probe Models MN93-BK &...
  • Page 6: Introduction

    Analyzers (see § 4 for meter compatibility). Sensor 24" Model 193-24-BK ..........Cat. #2140.34 AmpFlex ® AmpFlex Sensor 36" Model 193-36-BK ..........Cat. #2140.35 ® AmpFlex Sensor 24” Model A196-24-BK ........Cat. #2140.75 ® MiniFlex Sensor 10" Model MA193-10-BK........Cat. #2140.48 ® Sensor 14" Model MA193-14-BK ........Cat. #2140.50 MiniFlex ®...
  • Page 7: Product Features

    2. PRODUCT FEATURES 2.1 Control Features 2.1.1 AmpFlex Models 193-24-BK, 193-36-BK & 196-24-BK ® Flexible sensor Sensor opening connector Shielded lead Custom 4-pin input connector Current Probes & Sensors for Power Quality Meters...
  • Page 8: Miniflex Model Ma193-Bk

    2.1.2 MiniFlex Model MA193-BK ® Flexible sensor Sensor opening device Shielded lead Custom 4-pin input connector Current Probes & Sensors for Power Quality Meters...
  • Page 9: Ac/Dc Current Probe Model J93

    2.1.3 AC/DC Current Probe Model J93 ZERO 300 V CA T IV 600 V CA T III Jaws 4-point CA connector Safety guard Zero adjustment knob Power ON /Low battery indicator Three-position switch: ON, OFF, battery test Current Probes & Sensors for Power Quality Meters...
  • Page 10: Ac Current Probe Models Mn93-Bk & Mn193-Bk

    2.1.4 AC Current Probe Models MN93-BK & MN193-BK Jaws Protective guard Two-position range switch (MN193 only) Jaw opening lever Shielded lead Custom 4-pin input connector Current Probes & Sensors for Power Quality Meters...
  • Page 11: Ac Current Probe Model Mr193-Bk

    2.1.5 AC Current Probe Model MR193-BK Jaws Protective guard Jaw opening lever Two-position range switch Shielded lead Zero adjustment Custom 4-pin input connector Current Probes & Sensors for Power Quality Meters...
  • Page 12: Ac Current Probe Model Sl261

    2.1.6 AC Current Probe Model SL261 Jaws Zero adjust knob Range selection switch Battery compartment screw Battery compartment cover BNC Adapter (sold separately - Cat. #2140.40) Current Probes & Sensors for Power Quality Meters...
  • Page 13: Ac Current Probe Model Sr193-Bk

    2.1.7 AC Current Probe Model SR193-BK Jaws Protective guard Jaw opening lever Shielded lead Custom 4-pin input connector Current Probes & Sensors for Power Quality Meters...
  • Page 14: Operation

    3. OPERATION The current probes and flexible sensors are used to measure the current flowing in a conductor or bus bar without opening the circuit. They also insulate the user from dangerous voltages in the circuit. The choice of current probe or sensor to be used depends on the amperage to be measured and the diameter of the cables or size of the bus bar.
  • Page 15 For Probes: ■ Press the jaw opening lever on the probe to open the jaws. ■ Clamp the probe around the conductor to be tested. For best results, center the conductor in the jaws of the clamp. For AmpFlex and MiniFlex Sensors: ®...
  • Page 16: Specifications

    8333, 8336 & PEL Series 24" (610mm) (12,000A) AmpFlex 193-36-BK 200mA to 10kA ® 8333, 8336 & PEL Series 36" (910mm) (12,000A) AmpFlex A196-24-BK ® 200mA to 10kA 8435 24" (610mm) (12,000A) MiniFlex MA193 200mA to 3000A ® 8333, 8336 & PEL Series 10"...
  • Page 17: Environmental

    11 x 10.4 x .98" 9.5 oz 10 ft (3m) 11.46" (290mm) 36" (910mm) (280 x 265 x 25mm) (220g) AmpFlex A196-24-BK ® 6.6 x 6.2 x .98" 7.7 oz 10 ft (3m) 7.64" (190mm) 24" (610mm) (170 x 158 x 25mm)
  • Page 18: Safety

    4.4 Safety Protection index IP 40 for the probes and IP 30 jaws open, according to IEC 60 529 ■ IP 65 for the AmpFlex according to IEC 60 529 ® ■ IK 04 according to IEC 50102 Drop test: According to IEC 61010-1 Electrical safety according to IEC 61010-2-032.
  • Page 19: Maintenance

    5. MAINTENANCE Use only factory specified replacement parts. AEMC will not be held responsible ® for any accident, incident, or malfunction following a repair done other than by its service center or by an approved repair center. CAUTION: Risk of electric shock. Disconnect the instrument from any source of electricity.
  • Page 20: Model J93

    5.2.3 Model J93 ■ Insert a tool, not more than 3mm in diameter, in the hole in the battery compartment cover. ■ Push to unlock the battery compartment cover, then slide it off. ■ Remove it completely by hand. ■ Remove the battery and the shim from the compartment. ■...
  • Page 21: Repair And Calibration

    5.3 Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be scheduled back to our factory Service Center at one-year intervals for recalibration, or as required by other standards or internal procedures. For instrument repair and calibration: You must contact our Service Center for a Customer Service Authorization Number (CSA#).
  • Page 22: Limited Warranty

    5.5 Limited Warranty The current probes and sensors are warranted to the owner for a period of one year from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC Instruments, not by the distributor from whom it was ®...
  • Page 24 12/15 99-MAN 100391 v4 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 15 Faraday Drive • Dover, NH 03820 USA • Phone: (603) 749-6434 • Fax: (603) 742-2346 www.aemc.com...

Table of Contents