Ebyte E104-BT12NSP User Manual page 14

Tlsr8253f512 serial patch sig mesh group module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
Respond
0x40
Request:02 C0 00
Example
Respond:06 40 00 DATA[3]
Description:
This instruction is only applicable to E104-BT12SP-L, E104-BT12SP-N to obtain network
addresses and configure networks
DATA analysis
Unorganized network:
DATA[0] =0x00,DATA[2],DATA[3]0
Network :
DATA[0] =0x01,DATA[2],DATA [3] is the module network address.
4.2.1.2 Baud Settings
Operational code
Request
0x01
Respond
0x01
Order
03 C0 01 xx
Example
Note:
This instruction be suitable for operation of e104-BT112-L and e104-BT12SP-N
Example: 03 C0 0E 02,Modification successfully returns 03400E02 if parameter is out of range
returns 034000010D
4.2.1.3 Baud read
Operational code
Request
0x02
Respond
0x02
Example
Order
02 C0 02
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
06 40 00 data
Parameter
Baud rate serial number to be set (range 0x00~0x07)
Returns the current baud rate serial number.
Baud rate specification
Xx represents the baud rate label to be set(0x00~0x07)
00:230400
01:128000
02:115200
03:76800
04:57600
05:19200
06:9600
07:4800
Parameter
None
Returns the serial number of the set baud rate
Return
03 40 02 xx
Explanation
xx represents the baud
rate
number
00:230400
01:128000
02:115200
E104-BT12NSP User Manual