  • Page 1 Chengdu Ebyte Electronic Technology Co., Ltd. E78-900M22S User manual E104-BT12NSP User Manual TLSR8253F512 Serial Patch SIG Mesh Group Module Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 2: Table Of Contents

    ............................. 32 7.3 T HE ERROR RATE IS TOO HIGH 8. WELDING INSTRUCTION..................................32 ..........................32 8.1 R EFLOW ELDING EMPERATURE ............................. 33 8.2 B ACKFLOW ELDING URVE 9. REVISION HISTORY..................................34 ABOUT US........................................ 34 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 3: Disclaimer

    E104-BT12NSP User Manual Disclaimer EBYTE reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited.
  • Page 4: Product Overview

     Supports low power consumption (SIG standard low power consumption)  support crosstalk wake-up  1.3 Application smart home, etc.;  Building automation;  Luminaires;  Wireless sensor networks;  Internet of Things.  Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 5: Technical Parameters

    Instantaneous power consumption at 10 dBm output current(mA) Power Receiving current(mA) consumption Turn-off current 13.32 (μA) maximum emitting power [dBm] Receiving sensitivity [dBm] Air data rate: 1Mbps GFSK(bps) Air data rate 125k Default 1Mbps Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 6: Dimension And Pin Definition

    Chengdu Ebyte Electronic Technology Co., Ltd. E78-900M22S User manual Main parameter Description Note Distance TClear and open, antenna height 2.5 m, airspeed 1 Mbps. FIFO 60Byte Single transmission maximum length Crystal oscillator 24MHz Modulation GFSK GFSK Package Connector 1.27mm 4800~230400bps...
  • Page 7: Basic Operation

    When designing power supply circuits for modules, it is often recommended to keep more than 30 percent of the  spare, which is advantageous for the whole machine to work steadily over a long period of time. Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 8: Basic Circuit

    Keep away from the 2.4 GHz TTL protocol in some physical layers, e.g. USB 3.0;  The module must not be mounted inside the metal housing, which will greatly weaken the transmission distance.  3.2 Basic Circuit Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 9: Functional Introduction

    The biggest advantage of this module is that it can relay any data in the network. Any module can be relayed and received at the same time. The module's data signal coverage is about 50 meters. The following is a functional schematic. A->C 70M C->E 70M B->D 70M Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 10: Basic Concept

    E, where A sends data to B, B to C, C to D, D to E Basic Concept 4.1.1 NetKey Network keys are used to protect network-layer communications.is a key generated by using a random number generator that meets the core specifications.(See Mesh Profile 3.86) Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 11 Mesh network control with mobile phone-side APP (the data compression package contains APP-related SDKs for customer development). A single device supports only one role. In the EBYTE scheme, our modules support three roles: provision node and mesh node, LPN node, which is the device responsible for networking.
  • Page 12 Light HSL Hue Server 130A Light HSL Saturation Server 130B Light HSL Client 1309 VENDOR MODEL(pass-throug model ID) 0001A8 Generic OnOff Server 1000 Generic OnOff Client 1001 Master Address+1 Generic Level Server 1002 Generic Level Client 1003 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 13: Data Format

    An address corresponds to an element from the Model introduction above. We can call it an elemental address. It is the unique address assigned to a Node node by a PROVISION device during a PROVISION process. Each Node device in the same Mesh network may have multiple addresses.E104-BT12USP is a Provision device and E104-BT12NSP is a Node device.
  • Page 14 Request 0x02 None Respond 0x02 Returns the serial number of the set baud rate Example Order Return Explanation 03 40 02 xx xx represents the baud rate number 00:230400 02 C0 02 01:128000 02:115200 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 15 Operational code Parameter Request 0x04 None Respond Returns the serial number of the power currently in 0x04 Example Order Return Explanation 03 40 04 xx xx represents power number 00:+10dBm 02 C0 04 01:+8dBm 02:+6dBm Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 16 Request: 02 C0 06 Example Respond: 03 43 15 00 Note: This instruction is applicable to E104-BT12SP-L and E104-BT12SP-N configuration operation. Status value 00 indicates success. 4.2.1.8 MAC Read Operation Parameter al code Request 0x07 None Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 17 DATA[0`3] : pocet_id DATA[4`9] : pocet_mac DATA[10-26] : pocet_sec The application method for this triad and the instruction usage method are shown in the "Apply Triad to Ali and Set Up Device Information " document Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 18 Chengdu Ebyte Electronic Technology Co., Ltd. E78-900M22S User manual 4.2.1.12 Set LPN to Time Out and Return to Sleep Operation Parameter al code Request 0x0B None Respond 0x0B Set time-out sleepout. Request:04 C0 0B TIME Example Respond:05 40 0B TIME Note:Default 5000 ms...
  • Page 19 4.2.1.17 Reading LPN Unstructured Networks to Sleep Time Operation Parameter al code Request None 0x10 Respond Set time-out sleepout. 0x10 Request:04 C0 10 Example Respond:05 40 10 TIME Note: This instruction be for E104-BT12SP-L configuration operation only Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 20 Order(1byte) Target address (2 bytes) Original address Data bytes) Primary address of Target Source device master 0x42 Valid data device address For example: Device 0001 sends the hexadecimal data of "00112233445566778899" to device 0004 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 21: Switch Dio

    Switch DIO2 to low C device lights out, DIO2 to high, C device lights on. 6. Quick get start This chapter introduces how E104-BT12SPs form networks quickly and how to control network message transmission and delivery. Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 22: Restore Factory Settings Restore

    Chengdu Ebyte Electronic Technology Co.,Ltd. E104-BT12NSP User Manual 6.1 Restore factory settings restore Send the following instruction 02 C006 and you'll receive a return 0343 0600, E104-BT12NSP in the same format as the E104-BT12LSP instruction. Baud rate:115200, other8N1, do not return to change lanes.
  • Page 23 6.2.3 Mobile phone APP access and control devices 6.2.3.1 Access to the network 1. Open the APP and click this plus sign 1. If there is an unstructured network around, the following diagrams will appear in sequence. Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 24 Chengdu Ebyte Electronic Technology Co.,Ltd. E104-BT12NSP User Manual Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 25 4. When you press the length of the lamp, it will appear on the page as shown below, while sliding colored circles will change the color of the lamp to the color you to the color you want. Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 26 E104-BT12NSP User Manual 6.2.3.2 Publishing and Subscribing (Grouping) 1. Pressing multiple devices in turn into GROUP and then ticking the options on this page represents that you are dividing your devices into this group Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 27 Chengdu Ebyte Electronic Technology Co.,Ltd. E104-BT12NSP User Manual 2. When grouping is successful, group control can be carried out through GROUP on the mobile phone homepage Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 28: Sig Messages

    08 41 0002 0001 8204 01 E104-BT12SP sends the light off command (generic onoff command) command to control the network equipment (See Mesh Model 3.2.1.2 Generic OnOff Set for more information.) Send 09 C1 0002 8202 00000000 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 29: Transmission Of Information

    For example: Device 0002 sends hexadecimal data of "82 02 01 00 00 00" to device 0004 Sender 09 C2 0004 8202 01 00 00 00 Receiver 0C 42 02 00 04 00 82 02 01 00 00 00 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 30 09 C2 0004 8202 01 00 00 00 Receiver 0C 42 02 00 04 00 82 02 01 00 00 00 6.4.2.1 Acquisition of Group Addresses using APP Add 1 down to the address shown below. Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 31: Low Power Consumption (E104-Bt12Lsp)

    Temperature, humidity and same frequency interference can lead to higher packet drop rate;  The ground absorbs and reflects radio waves, and the test results are poor near the ground.  Sea water absorbs radio waves so much that the beach test results.poor;  Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 32: Module Is Easy To Damage

    Peak temperature(Tp) Peak temperature 220-235℃ 230-250℃ Aveage ramp-down rate(Tp to Tsmax) Average descent rate 6℃/second max 6℃/second max Time from 25℃ to peak Time 25℃ to peak temperature 6 minutes max minutes max temperature Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 33: Backflow Welding Curve

    Chengdu Ebyte Electronic Technology Co.,Ltd. E104-BT12NSP User Manual 8.2 Backflow Welding Curve Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 34: Revision History

    Initial version About us Technical support: support@cdebyte.com Documents and RF Setting download link: www.ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ------------------------------------------------------------------------------------------------- Phone: +86 028-61399028 Web: www.ebyte.com Address: B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China...