Test Summary
2.2.7
SOFTWARE
Unzip BQ2415xSetup.zip and double click on the "SETUP.EXE" file. Follow the installation steps.
2.3

Equipment Setup

(A) Set the power supply #1 for 5V ± 100mV DC, 2.0 ± 0.1A current limit and then turn off supply.
(B) Connect the output of power supply #1 in series with a current meter (multimeter) to J1 (DC+, DC–).
(C) Connect a voltage meter across J1 (DC+, DC–).
(D) Connect the Load #2 in series with a current meter (multimeter) to J2 (BAT+, BAT–). Make sure a
voltage meter is connected across J2 (BAT+, BAT–). Turn on the Load #2. Use the constant voltage
mode. Set the output voltage to 2.5V.
(E) Turn off Load #2.
(F) Connect J5 to HPA172 kit by 10-pin ribbon cable. Connect the USB port of the HPA172 kit to the USB
port of the computer. The connections are shown in
To
Computer
USB port
(G) Installed jumpers per
Spin
HPA256-001
(bq24150)
HPA256-002
(bq24151)
HPA256-003
(bq24152)
HPA256-004
(bq24150A)
HPA256-005
(bq24151A)
4
bq24150/150A/151/151A/152 YFF EVM (HPA256)
Figure 1. Connections of the HPA172 Kit
Table 1
Table 1. Factory Jumper Settings
JMP1
JMP2
(-LED-) ON
(-LO-) ON
(-LED-) ON
(-LO-) ON
(-LED-) ON
(-LO-) ON
(-LED-) ON
(-LO-) ON
(-LED-) ON
(-LO-) ON
Copyright © 2008–2011, Texas Instruments Incorporated
Figure
1.
JMP3
JMP4
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
SLUU321C – June 2008 – Revised June 2011
www.ti.com
10-pin
Ribbon
Cable
To EVM
JMP5
ON
ON
ON
ON
ON
Submit Documentation Feedback

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bq24150aBq24151Bq24151aBq24152Hpa256

Table of Contents