Final Installation; Maintenance - Grohe Grohtherm 1000 34 160 Manual

Hide thumbs Also See for Grohtherm 1000 34 160:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6

Final installation

1. Remove the mounting template, see fold-out page III fig. [8].
2. Fit sleeve (J).
3. Install holder (K) and fit sleeve (L), see fig. [9].
4. Grease the seals (M1) with the special grease supplied and
install escutcheon (M) with srews (N), see fig. [10].
If the thermostat has been installed at too great a depth,
this can be adjusted by 27.5mm with an extension set (see
fold-out page II, ref. No. 47 200).
Installation of the flow control knob and adjustment of the
economy stop, see fold-out page III figs. [11] to [13].
• The flow rate is limited by the economy stop (O) supplied,
see fig. [11].
To install the flow control knob, proceed as follows:
1. Close the ceramic headpart (P) by turning clockwise.
2. Install the economy stop (O) in the desired position.
For possible settings, see fig. [12].
3. Fit splined adapter (Q), see fig. [13].
4. Install flow control knob (R) so that the button (R1) is at top.
5. Reinstall screw (S).
6. Fit cap (T).
If a higher rate is desired, the stop can be overridden by
depressing the button (R1).
Reversed connection (hot on right - cold on left). Replace
thermostatic compact cartridge (Y), see Replacement Parts,
fold-out page II,Prod. no. 47 175 (1/2").
Adjustment
Installation of the thermostat knob and temperature
adjustment, see fold-out page IV figs. [14] and [15].
• Before the mixer is put into service if the mixed water
temperature measured at the point of discharge varies from
the specified temperature set on the thermostat.
• After any maintenance operation on the thermoelement.
1. Open the shutt-off valve and check the temperature of the
water with a thermometer, see fig. [14].
2. Turn the adjusting nut (U) clockwise or anticlockwise until
the water temperature reaches 38 °C.
3. Install temperature control handle (V) so that the button (V1)
is at top, see fig. [15].
4. Reinstall screw (W).
5. Fit cap (X).
Temperature limitation
The safety stop limits the temperature range to 38 °C.
If a higher temperature is desired, the 38 °C limit can be
overridden by depressing the button (V1), see fig. [15].
Temperature limit stop
If the temeprature limit stop should be 43 °C, use handel ref.
No. 47 739 (see fold-out page II.)
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be drained separately, since non-return valves
are installed in the hot and cold water connections.
The complete thermostat assemblies and non-return valves
must be unscrewed and removed.

Maintenance

Inspect and clean all parts, replace if necessary and grease
with special valve grease.
Shut off cold and hot water supplies.
I. Thermostatic compact cartridge (Y), see fold-out page IV,
fig. [16] and [17].
• Loosen screw ring (Z) using a 34mm tool.
• If necessary, lever out thermostatic compact cartridge (Y)
via recess (Y1).
• Remove screw ring (Z).
Install in reverse order.
Observe the correct installation position of the
thermostatic compact cartridge (Y).
Readjustment is necessary after every maintenance operation
on the thermostatic compact cartridge (see Adjusting).
II. Non-return valve (AB), see fold-out page IV fig. [16]
and [18].
Reassemble in reverse order.
III. Ceramic headpart (P), see fold-out page IV fig. [16]
and [18].
Reassemble in reverse order.
Observe the correct mounting positions!
Replacement parts, see fold-out page II ( * = special
accessories).
Care
For directions on the care of this fitting refer to the
accompanying Care Instructions.
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grohtherm 1000 34 161Grohtherm 1000 34 162

Table of Contents