Page 1
DFOE3 DFOE4 DFOE6 Throughout this manual statements Donaldson Company reserves the right to change design indicating precautions necessary to and specifications without prior notice. avoid equipment failure are referenced in a Illustrations are for reference only as actual product may Note.
Page 2
Donaldson Torit dust collection equipment is not equipped with fire extinguishing or explosion protection systems. • DO NOT allow sparks, cigarettes or other burning objects to enter the hood or duct of any dust or fume control equipment as these may initiate a fire or explosion.
This manual contains specific precautionary statements relative to worker safety. Read thoroughly and comply as directed. Discuss the use and application of this equipment with a Donaldson Torit representative. Instruct all personnel on safe use and maintenance procedures. Data Sheet...
唐纳森(无锡)过滤器有限公司 Donaldson (Wuxi) Filters Co.,Ltd. 1.0 Product Introduction 2.0 Installation The dust collector is used for the collection of Ensure all persons carrying out work on the airborne dust and particulate. Whether in supplied equipment follow any relevant answer to the problem of air pollution, or as...
DFOE 3,4,6 3.0 Start-up and Operation 2.3 Inlet Duct Connection Check that the outlet of the fan is free of The inlet collar is integrated with the unit, it is debris before starting. shown on figure 3. Make sure the dust disposal system is properly installed under the hopper.
唐纳森(无锡)过滤器有限公司 Donaldson (Wuxi) Filters Co.,Ltd. 4.0 Service 4.2 Replacing of Filter Elements Caution: Caution When the airflow is low or the differential pressure is too high and alarm, must change Disconnect electrical power before the filter elements. After operating more than servicing.
DFOE 3,4,6 5.0 Trouble shooting WARNING Disconnect all power before servicing to prevent injury or extensive damage. Direct compressed air supply towards human body or equipment will cause serious injury, shut off and bleed compressed air supply before servicing any compressed air components.
Page 10
唐纳森(无锡)过滤器有限公司 Donaldson (Wuxi) Filters Co.,Ltd. Problem Probable Cause Remedy Fan does not start Not wired correctly. Check and correct internal motor wiring for proper connections for your voltage (see Wiring Diagram) Proper wire size not used for Rewire per national and local electric codes motor for proper wire size.
Page 11
DFOE 3,4,6 Problem Probable Cause Remedy Insufficient airflow Fan wheel rotating wrong Check fan rotation. Refer to rotation sticker on fan housing. Openings not properly Check doors, that they are closed and sealed tightened securely. Also check hopper area that openings are closed off and that the hopper dust disposal is installed.
唐纳森(无锡)过滤器有限公司 Donaldson (Wuxi) Filters Co.,Ltd. 6.0 Control Panel Figure 6 Control Panel 6.1 Control panel functions 6.2 Operation The “Local/Remote” selection switch is for Ensure that the control panel is correctly LOCAL or REMOTE fan motor on/off control installed onto the dust collector before selecting.
Page 13
DFOE 3,4,6 When the “Local/Remote” selection There is overload protection for the fan switch is set at “Remote” position, the motor, the setting of AMPs according to start/stop of the fan motor can be the nameplate of the fan motor. When the controlled remotely.
唐纳森(无锡)过滤器有限公司 Donaldson (Wuxi) Filters Co.,Ltd. Spare Parts Item Description Part number Filter Assembly-Ultra Web FR P19-1920 Diaphragm valve with Solenoid Valve 8PP- AK00144-21 Access cover 3EA-AD33387-01 Access door gasket 8PP-AD30021-01 Delta P-C01 115V/230V 8PP-AK01004-00 Note: When ordering parts, give model number and serial number of dust collector,...
Page 18
Such a refund will be in the full extent of Donaldson’s liability. Donaldson shall not be liable for any other costs, expenses or damages whether direct, indirect, special, incidental, consequential or otherwise. The terms of this warranty may be modified only by a special warranty document signed by a Director, General Manager or Vice President...
Need help?
Do you have a question about the DFOE3 and is the answer not in the manual?
Questions and answers