Sanyo SPW-X253G56 Service Manual page 60

Split system
Table of Contents

Advertisement

E.
Check. auxiliary relay. (1Y or 2Y)
• Check coil resistance of
auxiliary relay.
F.
Check indoor fan motor thermal protector (49FMI)
• Disconnect the socket from 9P (WHT) connector.
• Check the continuity
between No. 8 and No.9
poles of the 9P socket.
The thermal protector (49FMI)
is operated.
• Check fan rotation.
Rotate the fan gently once
or twice by hand.
• Check fan motor capacitor.
G. Check fuse on the P.C.B. Ass'y in the indoor unit.
• Check fuse on the P.C.B.
Ass'y in the indoor unit
for continuity.
4
• Check transformer. (TR)
• Check resistance of indoor
fan motor winding.
• Check resistance of louver
motor winding.
(1Y or 2Y)
0620_X_S
No continuity.
Fan cannot
be rotated.
OK
When the fuse blows.
OK
(FMI)
OK
(LM)
OK
Check fan casing
for foreign matter
on the inside.
Fan motor burnout
or foreign matter
in bearing.
• Check resistance of drain
pump winding.
OK
• Check resistance of dew
proof heater.
(DPH)
OK
• Check coil of compressor
motor magnetic contactor.
OK
• P.C.B. Ass'y is defective.
– 60 –
4. Service procedures
Remove foreign
matter or repair.
Repair or replace.
0621_X_S
(DP)
(52C)
0622_X_S
SM830042