Fitting The Insulation (≤ A275-L); Fig. 50: Fitting The Insulation (A275-L And Smaller) - ABB A255-L35 Original Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A200-L
8 Disassembly and assembly / 8.15 Fitting the insulation (≤ A275-L)
5. Coat remaining nuts with high-temperature grease, fit and then tighten crosswise, ini-
tially to the pre-tightening torque and then to the tightening torque.
6. Remove the lifting gear.
7. Connect the flange of the gas inlet casing and the bellows.
8.15
Fitting the insulation (≤ A275-L)
Fig. 50: Fitting the insulation (A275-L and smaller)
1. Fit flange connection between gas inlet casing (51001) and bellows.
2. Fit the insulation jackets (51200) on the gas inlet casing (51001) with the screws.
3. Fit connecting plates of insulation jackets with screws.
4. Fit insulation jackets with screws on gas outlet casing (61001).
© Copyright 2020 ABB. All rights reserved.
HZTL4036_EN
Rev.R
October 2020

Advertisement

Table of Contents
loading