ABB A255-L35 Original Operation Manual page 57

Table of Contents

Advertisement

Operation Manual / 4 Product description / A200-L
5 Operation and service / 5.2 Service work
Take note of correct customer spare part set (see chapter
Remove the filter silencer.
u
Clean filter silencer and check for damage.
u
Dismantle the wall insert.
u
Check axial clearance A.
u
Clean wall insert, diffuser and compressor casing and check for damage.
u
Remove the gas inlet casing and dismantle the nozzle ring and cover ring.
u
Clean the nozzle ring and cover ring and check for damage.
u
Dismantle, inspect and balance the rotor.
u
Replace the plain bearing
u
5.2.5
Service work according to instructions of enginebuilder
Clean or replace the oil filter located in the supply pipe to the turbocharger while the en-
u
gine is stopped, in accordance with the instructions of the enginebuilder.