Fitting The Insulation (≤ A275-L); Fig. 53: Fitting The Insulation (A275-L And Smaller) - ABB A200-L Operation Manual

Turbocharger
Hide thumbs Also See for A200-L:
Table of Contents

Advertisement

Operation Manual / A200-L
9 Disassembly and assembly / 9.15 Fitting the insulation (≤ A275-L)
4. Coat two nuts with high-temperature grease and fix gas inlet casing in two opposite po-
sitions.
5. Coat remaining nuts with high-temperature grease, fit and then tighten crosswise, ini-
tially to the pre-tightening torque and then to the tightening torque.
6. Remove the lifting gear.
7. Connect the flange of the gas inlet casing and the bellows.
9.15
Fitting the insulation (≤ A275-L)
Fig. 53: Fitting the insulation (A275-L and smaller)
1. Fit flange connection between gas inlet casing (51001) and bellows.
2. Fit the insulation jackets (51200) on the gas inlet casing (51001) with the screws.
3. Fit connecting plates of insulation jackets with screws.
4. Fit insulation jackets with screws on gas outlet casing (61001).