INSTALLATION (NEW CONSTRUCTION) CONTINUED
7. Refer to wiring diagram on page 5.
Follow all the local electrical safety
codes as well as the National Electrical
Code (NEC). Using UL approved wire
nuts, connect house power wires to
ventilating fan wires. (Fig.5)
CA U T I O N
Mount junction box cover
carefully so that lead wires
are not pinched.
8. Insert fan body and slide into adaptor assy with some
strength, untill the flange overlaps the Flex-Z Fast
bracket. Secure the fan body to Flex-Z Fast
by using 2 self-drilling screws, plug connector to
receptacle and secure the fan body to adaptor by
using machine screw (M4X8). (Fig.6)
CAUTION
CAUTION
Secure machine screw (M4X8) to the
suitable hole and not touch the Flex-Z Fast
bracket. Please fix the screw carefully to
avoid screw slip teeth.
9. Finish ceiling work. Ceiling hole should be aligned
with the inside edge of the flange. (Fig.7)
10. Insert the grille mounting spring on the wiring
side into the slot and insert the plug connector
into the housing of the lighting unit. (Fig.8)
CAUTION
Before turn on the light, make sure the
connector at the correct position. If not,
the lighting can't work.
The claw of connector must latch the rib
completely.
IMPORTANT:
Replace the sensor cover before the installation
(only for plug-in Motion sensor module FV-MSVK1). (Fig.9)
Keep on pressing the clasps when removing the ornamental cover.
Insert the sensor cover (attachment for FV-MSVK1) into slot.
Keep on pressing the clasps when removing the ornamental cover.
Ornamental cover
Conduit
Junction
box
Live
(N.Light)*
Neutral
Live
(Light)
* Night Light
TM
 
Gloves
Earth ground
Live (Fan)
Neutral
Two red wires (Connect to a
general manual wall switch)
TM
bracket
Plug connector
Receptacle
TM
After finishing the ceiling job, fill gap between flange
and ceiling with caulk or other sealant to prevent air
leakage.
Ceiling
Insert the sensor cover (attachment for FV-MSVK1) into slot.
Sensor cover
Earth ground
Machine
screw
(M4X8)
2 Self-drilling
screws
Ceiling
Unit: inches (mm)
Mounting spring
Clasp
Motion sensor
(FV-MSVK1 only)
Lighting unit
W H I TE
BLA CK
RED
B L UE
GREEN
Wire nuts
Switch box
L
N
120 VAC
LINE IN
Fig.5
Fig.6
Fig.7
Fig.8
Fig.9
9
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fv-1115vkl2Fv-0511vksl2

Table of Contents