Panasonic FV-05-11VKS1 Installation Instructions Manual

Panasonic FV-05-11VKS1 Installation Instructions Manual

Ventilating fan
Hide thumbs Also See for FV-05-11VKS1:

Advertisement

FV-05-11VKS1
FV-05-11VK1
FV-11-15VK1
Thank you for purchasing this Panasonic product.
Model No.
Contents
GENERAL SAFETY INFORMATION
INDICATION (PLUG 'N PLAY FUNCTION DEVICES)
MAINTENANCE (CLEANING)
PRODUCT SERVICE
2-3
4
4
4
5
5
5
5-6
6-7
7
7
8
8-10
10
11
BACK COVER
BACK COVER
BACK COVER

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic FV-05-11VKS1

  • Page 1: Table Of Contents

    MOTION (PLUG ‘N PLAY FUNCTION DEVICES) INSTALLATION (PLUG ‘N PLAY FUNCTION DEVICES) INSTALLATION (NEW CONSTRUCTION) 8-10 INSTALLATION (RETROFIT) MAINTENANCE (CLEANING) PRACTICAL GUIDE TO INSTALLATION BACK COVER SPECIFICATIONS BACK COVER PRODUCT SERVICE FV-11-15VK1 BACK COVER Thank you for purchasing this Panasonic product.
  • Page 2 For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed.
  • Page 3 WARNING Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40. Do not disassemble the unit for reconstruction. It may cause fire or electric shock. When this product is no longer being operated, please remove the product to prevent the possibility of falling.
  • Page 4: Please Read Prior To Installing This Fan

    Multi-Speed module, these models kick up to a maximum level of 150 CFM for the FV-11-15VK1 and 110 CFM for the FV-05-11VKS1 and FV-05-11VK1 either when the switch is turned on or activated by the optional Condensation Sensor module or the optional Motion Sensor module.
  • Page 5: Supplied Accessories

    Green Green FEATURE [For models of: FV-05-11VKS1, FV-05-11VK1, FV-11-15VK1.] The WhisperGreen Select Line of ventilation fans employs innovative, state-of-the-art technologies that provide a number of customizable unique features that lead to improved indoor air quality. Please read the installation manual first in order to realize the benefits of this customizable, modular fan.
  • Page 6 The Pick-A-Flow switch on the face of all WhisperGreen Select fans allows the option to choose 50 – 80 – 110 CFM for the FV-05-11VK1, FV-05-11VKS1 or 110 – 130 – 150 CFM for the FV-11-15VK1. These fans can run continuously or intermittently, depending upon the needs of the owner.
  • Page 7: Description For Night Light Module

    INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED PLUG ‘N PLAY Modular Component Accessories Sold Separately, Not Included With Base Model Fan FV-MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when using in combination with the FV-VS15VK1.
  • Page 8: Installation (Plug 'N Play Function Devices)

    You can purchase the specified Plug ‘N Play devices that are explained on page 6-7 and install them in positions . Position can only be used with Multi-Speed module (model FV-05-11VKS1 already have this control installed), position can be used for any of the other optional control modules.
  • Page 9 INSTALLATION (NEW CONSTRUCTION) CONTINUED 7. Refer to wiring diagram on page 5. WHITE BLACK Follow all the local electrical safety codes as Conduit well as the National Electrical Code (NEC). GREEN Earth ground Wire nuts Using UL approved wire nuts, connect house power wires to ventilating fan wires.
  • Page 10: Installation (Retrofit)

    INSTALLATION (NEW CONSTRUCTION) CONTINUED 13. Adjust Pick-A-Flow switch; if used, adjust the FV-VS15VK1 Multi-Speed module. (Fig.10) Ceiling Refer to indication on page 6. Grille 14. Insert the other mounting spring into the slot as shown and mount grille to fan body. (Fig.11) CAUTION Fig.10 Mount grille carefully so that lead wire is...
  • Page 11 WARNING Mounting spring Disconnect power source before working Grille on unit. Slot Gloves Fig.15 CAUTION Routine maintenance must be done every year. Please wear gloves during Clasp the cleaning work. Ceiling Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan.
  • Page 12: Practical Guide To Installation

    Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada). Two Riverfront Plaza, Newark, NJ 07102...

This manual is also suitable for:

Fv-11-15vk1Fv-05-11vk1

Table of Contents