Panasonic FV-0511VQL1 Installation Instructions Manual

Panasonic FV-0511VQL1 Installation Instructions Manual

Hide thumbs Also See for FV-0511VQL1:

Advertisement

Representative models:
READ AND SAVE THESE INSTRUCTIONS
Thank you for purchasing this Panasonic product.
Please read these instructions carefully before attempting to install, operate or service
the Panasonic product. Please carefully read the "GENERAL SAFETY INFORMATION"
Failure to comply with instructions could result in personal injury or property damage.
Please explain to users how to operate and maintain the product after installation,
and this booklet should be presented to users.
Please retain this booklet for future reference.

INSTALLATION INSTRUCTIONS

Contents
FV-0511VQL1
FV-1115VQL1
FV-0511VQCL1
Ventilating Fan
FV-0511VQL1
Model No.
FV-1115VQL1
FV-0511VQCL1
----------------------------------------4
-----------------------------------------4
--------------------------4
-----------------------------------------5
-----------------------------------6
---------------------------------------------7
----------------------------------- 11
--------------------BACK COVER
--------------2~3
---------6
-----------------7
--------8~9
-----------------------10
------------------10~11
-----------11
1 1 Q C L 1 4 2 0 B

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic FV-0511VQL1

  • Page 1: Table Of Contents

    Thank you for purchasing this Panasonic product. Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Please carefully read the “GENERAL SAFETY INFORMATION” Failure to comply with instructions could result in personal injury or property damage.
  • Page 2: General Safety Information

    GENERAL SAFETY INFORMATION For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed.
  • Page 3 GENERAL SAFETY INFORMATION CONTINUED Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40. Do not disassemble the unit for reconstruction. It may cause fire or electric shock. A statement to the effect that when the product is to no longer be used, it must not be left in place but remove, to prevent it from possibly failing.
  • Page 4: Description

    40W incandescent lamp. Night light feature consumes around 0.1 to 0.4 W. (FV-0511VQCL1 only) This Panasonic ventilating fan model is equipped with a motion sensor and a humidity sensor that turn on automatically when motion is detected, when humidity increases rapidly, or when humidity rises above a 30% ~ 80% relative humidity set-point.
  • Page 5: Dimensions

    DIMENSIONS FV-0511VQL1 , FV-1115VQL1 Unit: inches (mm) 1 1/2 (37) 1 1/4 (30) 4 1/2 (114) 6 5/8 (169) FV-1115VQL1 7 1/2 (190) FV-1115VQL1 13 (330) Part name Part name Blade Lighting unit Fan body Grille Junction box Damper Adaptor...
  • Page 6: Wiring Diagram

    WIRING DIAGRAM FV-0511VQL1 , FV-1115VQL1 Fan body Junction box White Neutral Main control circuit AC120V 60Hz Live Black (Power supply) Main control Motor circuit Green (Ground wire) Blue Live N.Light AC120V White Neutral 60Hz Black Live Light (Power supply) FV-0511VQCL1...
  • Page 7: Operation (Fv-0511Vqcl1 Only)

    The Pick-A-Flow switch on the face of all WhisperCeiling ventilating fans allow the option to choose 50 – 80 – 110 CFM for the FV-0511VQL1 or 110 – 130 – 150 CFM for the FV-1115VQL1. These fans can run with constant air volume depending upon the needs of the owner.
  • Page 8: Installation (New Construction)

    INSTALLATION (NEW CONSTRUCTION) The fan position between joists from 16" to 24" Adaptor on center can be adjusted flexibly. Machine screw (M4X8) CAUTION Please wear gloves during the installation work as follow. 1. Disconnect plug connector from receptacle (Fig.6) Fan body and remove adaptor from fan body by removing the Fig.1 machine screw (M4X8) before installation.
  • Page 9 INSTALLATION (NEW CONSTRUCTION) CONTINUED 8. Insert fan body and slide into adapter assy with some strength, until the flange overlaps the Flex-Z Fast bracket. Secure the fan body to Flex-Z Fast bracket by using 2 self-drilling screws, plug connector to receptacle and secure the fan body to adaptor by using machine screw (M4X8).
  • Page 10: Installation (Retrofit)

    INSTALLATION (RETROFIT) WARNING Unit: inches (mm) Conduit Circular duct Joist Disconnect power source before working on unit. 4Tapping 1. Remove the existing fan and cut ceiling opening. ( ST4.2x20) screws Secure the Flex-Z Fast bracket to joists by drilling 4 tapping screws (ST4.2x20) which Ceiling (already existed) have been fixed on it.
  • Page 11: Practical Guide To Installation

    Voltage Frequency Noise Speed Power Weight diameter at 0.1"WG Model No. direction (Hz) (sones) (rpm) Ib.(kg) (inches) (CFM) <0.3 9.9(4.5) FV-0511VQL1 Exhaust 4 or 6 <0.3 1016 11.0 <0.3 FV-1115VQL1 Exhaust <0.3 10.4 10.1(4.6) 13.1 <0.3 <0.3 10.1(4.6) FV-0511VQCL1 Exhaust...
  • Page 12: Product Service

    Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada). Panasonic Corporation of North America Panasonic Canada Inc.

This manual is also suitable for:

Fv-0511vqcl1Fv-1115vql1

Table of Contents