3-2.4. Factory Settings
Parameter setting are not to be changed from fac-
tory settings without explicit written permission
from Big Lift LLC. To verify the parameter settings
proceed as follows and refer to
1.
Connect the Zapi Handset, refer to paragraph
3-2.1.
2.
Press the ENTER button (3,
the MAIN MENU.
3.
Press the ROLL down button (1) or the ROLL up
button (2) to find the PARAMETER CHANGE dis-
play.
4.
Press the ENTER button (3) to view the parame-
ters.
R6624
Figure 3-2 Zapi Handset
BL-J1-192-0315 - 11-19-2019
Table
3-2:
Figure
3-2) to enter
5.
Press the ROLL down button (2) or the ROLL up
button (1) to find the parameter to be checked.
6.
Press the SET up button (5) or the SET down but-
ton (6) until the factory setting is reached.
7.
Press the OUT button (4) to exit the parameters.
The confirmation request appears.
8.
Press ENTER button (3) to accept the changes or
press OUT button (6) to refuse the changes.
9.
Press the OUT button (6) again to return to Open-
ing Zapi Menu.
Table 3-2 Parameter Adjustments
Parameter
ACCELER. DELAY
RELEASE BRAKING
INVERS. BRAKING
PEDAL BRAKING
SPEED LIMIT BRK
BRAKE CUTBACK
MAX SPEED FORW
MAX SPEED BACK
CUTBACK SPEED
CUTBACK SPEED 2
CUTBACK SPEED 3
CURVE CUTBACK
DEADMAN BRAKING
HS (hard-soft) CUTBACK
FREQUENCY CREEP
MAXIMUM
CURRENT
INCHING SPEED
INCHING TIME
AUXILIARY TIME
Factory Setting
LEVEL = 4
LEVEL = 5
LEVEL = 7
LEVEL = 9
LEVEL = 2
LEVEL = 5
107 Hz
107 Hz
70%
50%
20%
60%
7
100%
1.20 Hz
9
0 Hz
0%
0.4