1.9

Sleep Mode

Outline
SLEEP Mode can be activated through the remote controller to keep the thermal comfort while
sleeping.
Details
SLEEP Mode continues operation at the target temperature for the first hour, then automatically
raises the target temperature slightly in case of cooling, or lowers it slightly in case of heating.
This prevents excessive cooling in summer and excessive heating in winter to ensure
comfortable sleeping conditions and also saves electricity.

1.10 POWERFUL Operation

Outline
In order to exploit the cooling capacity to full extent, the air conditioner can be operated by
increasing the indoor fan rotating speed and the compressor frequency.
Details
When POWERFUL button is pressed, the fan speed and target temperature are converted to
the following states for 20 minutes.
Operation mode
H = high fan
A = refer table below
Note
POWERFUL operation cannot be used together with ECO+ operation.
Functions and Control
ON signal of sleep operation
ON signal of sleep operation+operation ON signal
target temperature
<COOL or DRY>
target temperature
<HEAT>
COOL
HEAT
Mode
Model
Cool
FTK(X)
Heat
FTK(X)
OFF signal of sleep operation
run
sleep operation
1hr
1hr
(no offset on target
temperature)
(shift 0.5°C/0.9°F)
(shift 1.0°C/1.8°F)
Fan speed
H tap + A rpm
H tap + A rpm
09
80
150
150
Main Functions
operation OFF signal
(shift 1.0°C/1.8°F)
(shift 2.0°C/3.6°F)
Target temperature
Setting temperature -4°C (-7.2°F)
Setting temperature +6°C (+10.8°F)
12
18
90
80
80
24
80
80
31