4. LCD Display Information

Press "UP" or "DOWN" key to switch LCD display information. It will show battery pack and battery group
number before "Main CPU version checking" as below screen.
Selectable information
Battery pack numbers & Battery
group numbers

5. Code Reference

Related information code will be displayed on LCD screen. Please check inverter LCD screen for the operation.
Code
Description
If battery status is not allowed to charge and discharge after the communication
between the inverter and battery is successful, it will show code 60 to stop charging and
discharging battery.
Communication lost (only available when the battery type is setting as "Pylontech
Battery", "WECO Battery", "Soltaro Battery" or "BAK Battery".)
If battery status is not allowed to charge after the communication between the inverter
and battery is successful, it will show code 69 to stop charging battery.
If battery status must to be charged after the communication between the inverter and
battery is successful, it will show code 70 to charge battery.
If battery status is not allowed to discharge after the communication between the
inverter and battery is successful, it will show code 71 to stop discharging battery.
LCD display
Battery pack numbers = 3, battery group numbers = 1
After battery is connected and communication signal is not detected for 3 minutes,
buzzer will beep. After 10 minutes, inverter will stop charging and discharging to
lithium battery.
Communication lost occurs after the inverter and battery is connected successfully.
Then, buzzer beeps immediately.
61