Charge Mode Specifications; General Specifications - Kodak OGX 5.48a Installation & User Manual

Solar off grid inverter
Table of Contents

Advertisement

Table 3 Charge Mode Specifications
Utility Charging Mode
INVERTER MODEL
Charging Current (UPS)
@ Nominal Input Voltage
Bulk Charging
Voltage
Floating Charging Voltage
Overcharge Protection
Charging Algorithm
Charging Curve
Solar Input
INVERTER MODEL
Rated Power
Max. PV Array Open Circuit Voltage
PV Array MPPT Voltage Range
Max. Input Current
Table 4 General Specifications
INVERTER MODEL
Safety Certification
Operating Temperature Range
Storage temperature
Humidity
Dimension (D*W*H), mm
Net Weight, kg
Flooded
Battery
AGM / Gel
Battery
2.43Vdc (2.35Vdc)
2.25Vdc
OGX 5.48a
T1 = 10* T0, minimum 10mins, maximum 8hrs
OGX 5.48a
5000W
120Vdc~430Vdc
OGX 5.48a
CE
-10°C to 50°C
-15°C~ 60°C
5% to 95% Relative Humidity (Non-condensing)
140 x 295 x 468
12
37
100A
58.4
56.4
54Vdc
66Vdc
3-Step
Voltage
Current
450Vdc
18A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mksiii

Table of Contents