Equipment Setting And Caution - Inter-m PX-6216 Operation Manual

Audio matrix controller
Hide thumbs Also See for PX-6216:
Table of Contents

Advertisement

UDIO M TRIX CONTROLLER

Equipment Setting and Caution

Equipment Setting and Caution
1. EP CONNECTION
1) When connecting with EP equipment, please connect the matrix terminal of EP and emergency panel
connection terminal by using the EP connector supplied as an accessory of the PX-6216.
2) Connect the audio signal of PRE OUT of EP to EP audio input terminal on the top of PX-6216. Volume
control of EP input can be set in the equipment setting of operation program.
2. TIMER CONNECTION
1) When connecting with TIMER, connect the Timer contact point input terminal of ECS-6216MS and remote
output terminal of Timer.
2) Connect the audio signal of channel out terminal of Timer to the Timer audio input terminal on the top of
PX-6216. Volume control of Timer input can be set in the equipment setting of operation program.
3. D T LINK IN/OUT CONNECTION
1) Connect the LINK IN terminal of PX-6216 and LINK OUT terminal of DIB-6000 with UTP cable wired strait
or direct method. Connect the DIB-6000 to PC by using USB cable.
2) Set the termination switch terminal of DIB-6000 to LO D.
※ Communication error may occur if setup is incorrect.
3) Connect the other equipment including ECS-6216MS to each other through LINK IN/OUT terminal.
4) Set the TERMIN TION switch of the last equipment in the data link to LO D. Set the other equipment to
OPEN.
PC
Equipment 1
S/W: LOAD
IN
OUT
※ Keep the equipment orders when connecting it. Communication error may occur if setup is incorrect.
8
PX-6216
Equipment 2
Equipment 3
S/W: OPEN
S/W: OPEN
IN
OUT
IN
Equipment 4
S/W: OPEN
OUT
IN
OUT
Equipment 5
S/W: LOAD
IN
OUT

Advertisement