Table of Contents
loading

Summary of Contents for Dovre 2000 Series

  • Page 1 INBOUWHAARD / FOYER FIREPLACE / KAMINEINSATZ 2000-serie (1800; 2700; 2800; 2000S) 1800GL 2000 (2700; 2800) 2000S INSTALLATIEVOORSCHRIFTEN EN GEBRUIKSAANWIJZING INSTALLATION ET MODE D’EMPLOI INSTALLATION INSTRUCTIONS AND OPERATING MANUAL EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG 2000 03.27817.100...
  • Page 2: Table Of Contents

    Table of contents Foreword 32 Introduction ........................32 Safety ..........................32 Installation guideline ......................33 3.1. Preparatory measures .....................33 3.1.1. The chimney ......................33 3.1.2. Ventilation ......................34 3.1.3. Floor, walls ......................35 3.1.4. Combustible material round the fireplace ..............36 3.2. Preparation ........................36 3.2.1. Assembly of the legs .....................36 3.2.2.
  • Page 3: Foreword

    Save this booklet and pass to any subsequent user who can also profit by it. Introduction Your DOVRE purchase has made you the owner of a high quality product that sy m - bolizes a new generation of energy -saving and ecologically safe heaters, producing convection heat as well as radiant heat with optimum efficiency.
  • Page 4: Installation Guideline

    Installation guideline 3.1. Preparatory measures The fireplace should be hermetically connected to a well-functioning chimney, suffi- ciently enclosed to keep combustible materials (floor and walls) at a distance, and should be installed in a room with sufficient ventilation. Please inform about national or local norms and regulations concerning this subject. Your distributor will give y ou the necessary advice.
  • Page 5: Ventilation

    This precaution is particularly necessary in well-insulated rooms with mechanical ventilation. The DOVRE fireplace has been designed to produce most heat by means of convec- tion. Heat is mainly transmitted through the back panel, the lateral panels, and the smoke dome.
  • Page 6: Floor, Walls

    Convection air may be led to arrive from both the room and outside (other room, cellar, exte- rior) to the bottom side of the fireplace. In case convection air is supplied (directly or indirectly) from outside, it may also be useful as a supply of fresh air for combustion.
  • Page 7: Combustible Material Round The Fireplace

    Walls, ceiling Combustible walls behind, next to, or above the fireplace must be shielded with at least a 10 cm stone or brick w all and 10 cm insulation. Fireproof materials should be covered with at least 6 cm insulation. 3.1.4.
  • Page 8 2000S 2000 03.27817.100...
  • Page 9: Assembling The Flue Collar

    3.2.4. Assembling the flue collar Fix the flue collar on the smoke dome with bolts, nuts and collars. Assure proper sealing with kit or paste. 2000 03.27817.100...
  • Page 10: Installation Of The Fireplace

    3.3. Installation of the fireplace 3.3.1. Positioning and connection Put the fireplace at proper height. Make sure that it is stable and level and that the side panels are perpendic ular to the bottom plate. Put the fireplace far enough from the walls, so that minimum 10 cm of free air passage re- mains between the back of...
  • Page 11: Finishing

    Convection chamber: The convection chamber topside must be airtight. For that purpose, you can use a cover of steel, concrete, or any other fire-resistant material, and put extra insulation on top of it. Make sure that the cover is well horizontally placed. The cover must be installed at 30 cm at least above the smoke dome.
  • Page 12 Chimney Fireproof ce i- Combust i- ling ble ceiling Refractory cement or special con- ne ctor Opening against Cover plate eventual pressure buildup Insulation (min 10 cm) Convection Air outlet Fireproof wall min Stainless steel 10 cm pipe Insulation (if necessary Combustible wall Convection area Convection...
  • Page 13: Instructions For Use

    Instructions for use Fuel The only suitable fuels for this stove are wood, brown coal briquettes and charcoal (only for 2000S). No other fuels are allowed to be burnt, as they can inflict serious damage to your stove. Do not burn any treated wood either, such as scrap wood, dyed wood, impregnated or preserved wood, plywood or chipboard.
  • Page 14: Burning Wood

    4.3. Burning wood The best way to control the fire is to completely close the lower air slide, which you use to get the fire started, and to regulate the air supply with the upper air slide only (not for 1800). In case the air supply through the upper slide seems insuffi- cient, or if you would like to fan the fire, you can partially open the lower air slide for a while.
  • Page 15: Ash Removal

    4.5. Ash removal If your fireplace is equipped with an ashtray it must be emptied before the ashes reach the lower edge of the combustion grid. With the cold handle supplied, you can tilt the grid upwards and remove the ashtray from the device.
  • Page 16: Vorwort

    2000 03.27817.100...
  • Page 17: Annex 2 : Dimensions

    Annex 2 dimensions Anlage 2 : Abmessungen Bijlage 2 : afmetingen 2000S 2000 03.27817.100...
  • Page 18: Lüftung Des Räumes

    2000 2000 03.27817.100...
  • Page 19: Fussboden, Wände

    1800 2000 03.27817.100...
  • Page 20: Brennbares Material Um Den Kamin

    2800VG 2000 03.27817.100...
  • Page 21: Montage Der Füses

    2000 03.27817.100...
  • Page 22: Montage Der Rauchglocke Und Des Anschlusskragen

    Notified body: 1625 Wij, Nous, Wir, Dovre nv Nijverheidsstraat 18 B2381 Weelde verklaren bij deze dat de inbouwhaard 2000-serie conform is volgens de EN 13229. déclarons que le foyer 2000-serie est conforme au norme EN 13229. declare that the fireplace 2000-serie is in conformity with the EN 13229.
  • Page 24: Vollendung

    E & O E...