  • ENGLISH, page 17
• Install the cutting tool onto the machine and take necessary care for
installation.
• Do not touch the cutting tool while the machine is running.
• Do not operate your machine in the combustible and flammable environments.
• Keep the machine away from the humid and damp environments.
• Provide necessary lighting for the workplace.
• Unplug your machine from the power source before attempting to perform any
maintainance or repair.
• Shut your machine down after work is over.
• Clean the sawdust on the machine regularly.
• Keep your workplace in order. Any mess in the workplace increases the
accident risk.
• Make use of the recommended accessories for the machine.

2.5. Noise Levels

NORMATIVE REFERENCES: Acoustic test on the machine has been
carried out under the following conditions:
RUNNING CONDITIONS OF THE MACHINE DURING TEST:
Types of saw
Diameter of the saw
Saw speed
Cutting angle
The work material
Work dimensions
The bench on which the cutting machine is fixed : 1000 mm x 1000 mm x 900 mm ( h )
Measured average noise level
Noise level measured at operator's place
Environmental correction factor
The value of the correct noise level
: DRESS
: 250/300 mm
: 2850 rpm
: 0° , 15° , 22.5° , 30° , 45°
: Wood
: 30 x 30 mm
Idle
Lpm = 74,1 dB (A)
Lpm = 82,1 dB (A)
K = O,9
Lpc = 73,2 dB (A)
18
Under load
Lpm = 74,1 dB (A)
Lpm = 91,3 dB (A)
K = O,9
Lpc = 73,2 dB (A)