Redox section (mV)
To start the programming in screen 1, press ENTER for 3 seconds, enter the password, if any,
press ENTER, select Setup and press ENTER again, select Set-Point,
press ENTER and select mV:
ATTENTION :
IF NO KEY IS PRESSED FOR 90 SECONDS, THE DOSING STATION QUITS THE
PROGRAMMING MODE AND GOES BACK TO SCREEN 1.
If you press ENTER, the following will be displayed:
The cursor indicates the values which can be modified. Use the # $ keys to modify the data.
You can switch to other areas pressing the ! " keys.
ln our example, screen 6.3 shows that the chlorine pump is stopped at a value of 700 mV or more.
If the mV value decreases (decreasing chlorine), the pump will be started and the proportional dosing
will be increased, until 100% of the maximum flow rate at 650 mV has been attained. Should the mV
value continue to decrease, the pump would continue to work a the maximum flow rate. Complete
with ENTER to save the data. The "SETPOINT SAVED" message will appear on screen 6. Press
ESC several times to quit and go back to screen 1.
For your information: 750mV at pH 7.3 equals to a value of 1.5 to 2 mg/l of free chlorine depending
on the water quality and conductivity.
ON/OFF mode (Option) :
You can enter OFF instead of 00 % and ON instead of 100 %, if you do not want to enter the
values in % (do not forget to reduce the range, for ex.: 690 = ON / 700 = OFF).
Only use the tubes delivered for the connection of the pumps. The use of tubes other than
those delivered will cancel all guarantees.
- Suction tube (crystal type) and water return tube (opaque type) : 4 x 6 mm.
- Operating temperature: - 10 / + 60 °C.
If the regulation must be dismanteled to be transported, the doser tanks must be emptied to
avoid that any corrosive liquid escapes. Damage to the station due this will cancel all guarantees.
We recommend that you replace the cartridge of the circulaiton tank twice per year.
It is obligatory to connect the pool water entirely to earth, to avoid stray currents.
Screen 6.2
pH
% 650 mV =
Screen 6.3
700 mV =

RECOMMENDATIONS

Set-Point
% mV
100 %
00 %
13