"Reading" shows the value read by the sensor. Wait for the recorded value to settle. The value
below must be entered. Use the # or $ key, to enter the value read from the bottle of the
buffered solution depending on the temperature and press ENTER to store the calibration. If the
calibration has been carried out correctly, and if the sensor is in good condition, the following will
be displayed within a few seconds:
If the sensor does not provide for a reliable value, the following will be displayed:
If you quit the calibration mode, screen 4 will appear again.
Press the ESC key to go back to the previous page.
The main menu is shown (screen 1),
- Press ENTER for 3 seconds
- Enter the password, if programmed (when delivered, the password is "0000")
- Press ENTER again to go to screen 2
- Select "Parameter" using the following key ". The following will be displayed:
Delay : This value indicates how many minutes you have to wait until the dosing station will be
started. The delay can be set at 0 to 60 minutes and can be useful when it comes to
prevent the dosing pumps from working during the filter backwash.
During that time the dosing station is in the "STANDBY" mode.
Mode 1 : The pH and the Redox values are controlled simultaneously and corrected, if
necessary.
Mode 2 : The pH value is controlled first and the Redox value is neglected until the pH cut-in
value is obtained.
New Pw : New password.
The area can be changed using the ! " keys.
The # $ keys serve to enter modifications.
Press the ENTER key to confirm the modification. The following will be displayed on the
screen for several seconds:
OFFSET of mV
Screen 4.6
CAL at -010 mV
OFFSET of mV
Screen 4.7
UNCALIBRATED

START-UP DELAY AND PASSWORD

DELAY : % 00 MODE 1
Screen 5
NEW PW : 0 0 0
THE PASSWORD IS :
Screen 5.1
>
1 2 3
4 <
11
0