Procopi REGUL SYSTEM Instructions For Installation And Use Manual

Automatic dosing and regulation system

Advertisement

Quick Links

Automatic dosing
and regulation system
REGUL SYSTEM
INSTRUCTIONS FOR INSTALLATION AND USE
Thank you for buying a REGUL SYSTEM automatic dosing and regulation station. This is an efficient, powerful and reliable
product. Prior to installation and utilisation, the subsequent information must be read carefully. It contains important
recommendations as to handling and utilisation. Make sure not to lose this information and hand it to any potential user.

Advertisement

Table of Contents
loading

Summary of Contents for Procopi REGUL SYSTEM

  • Page 1 INSTRUCTIONS FOR INSTALLATION AND USE Thank you for buying a REGUL SYSTEM automatic dosing and regulation station. This is an efficient, powerful and reliable product. Prior to installation and utilisation, the subsequent information must be read carefully. It contains important...
  • Page 3: Table Of Contents

    OVERVIEW FOREWORD ............Page 4 INSTALLATION .
  • Page 4: Foreword

    FOREWORD GENERAL The REGUL SYSTEM dosing station has been designed for the measuring and dosing of chlorine and acid products in private pools and pools for housing areas. All information is indicated on a liquid cristal display. The keyboard serves to enter the data. The regulated parameters are displayed simultaneously.
  • Page 5 The electrical installation must be carried out in accordance with the valid regulations.The REGUL SYSTEM must be connected to a power supply of 220 V (± 10%) + earth. This power power supply must be connected to the filtrations system. To avoid an overload that may cause damage to the dosing station, it must not be connected directly in parallel to the pump.
  • Page 6: Connection Of The Circulation Tank

    CONNECTION OF THE CIRCULATION TANK Fig. 1 - Between the exits of the pump and the filter INJECTIONS FILTER PUMP POOL POOL HEATING BOOSTER PUMP FILTRATION CIRCUIT Fig. 2 - In the fitlter exit, before and after heating or after booster pump INJECTIONS FILTER PUMP...
  • Page 7: Installation Diagram

    FILTER CONNECTED TO CONTROL 230 V PANEL CHLORINE CORRECTION Tank alarm sensor Lateral Water probe extraction with regulation valve INJECTIONS FILTER PUMP POOL POOL BOOSTER PUMP HEATING FILTRATION CIRCUIT...
  • Page 8: Putting Into Operation

    PUTTING INTO OPERATION SENSORS WARNING The sensors will deteriorate rapidly, if not preserved in water. Therefore do not remove the sensors from their protective cover, unless you want to start the dosing station or the sensor holder is filled with water. Install the sensors inside the sensor holder.
  • Page 9: Sensor Calibration

    Special functions ON/OFF: The dosing station is not equipped with a power supply switch. To shut it off, press the # key for 4 seconds. OFF will be displayed on the screen. Press the # key for 4 seconds, to turn it on again. REINITIALIZATION: If you want to erase the memory with all data already entered, calibration and password, you must proceed as follows: 1) Shut off the power supply.
  • Page 10 Use the # $ keys to select CALIBRATE. Then press ENTER. The following will be displayed: Calibrate Screen 4 pH & To select the pH value press the ! " keys. Then press ENTER. The following screen is displayed : Reading : 7.24 pH Screen 4.1...
  • Page 11: Start-Up Delay And Password

    "Reading" shows the value read by the sensor. Wait for the recorded value to settle. The value below must be entered. Use the # or $ key, to enter the value read from the bottle of the buffered solution depending on the temperature and press ENTER to store the calibration. If the calibration has been carried out correctly, and if the sensor is in good condition, the following will be displayed within a few seconds: OFFSET of mV...
  • Page 12: Determination Of The Redox Cut-In Values

    DETERMINATION OF THE REDOX CUT-IN VALUE Proceed as follows to determine the Redox cut-in value: - The pH value must be regulated to obtain the desired value (in general 7.2 - 7.4). - Calibrate the sensor (see preceding chapter) and turn on the filter. The FRH pump must continue working.
  • Page 13: Recommendations

    Redox section (mV) To start the programming in screen 1, press ENTER for 3 seconds, enter the password, if any, press ENTER, select Setup and press ENTER again, select Set-Point, press ENTER and select mV: ATTENTION : IF NO KEY IS PRESSED FOR 90 SECONDS, THE DOSING STATION QUITS THE PROGRAMMING MODE AND GOES BACK TO SCREEN 1.
  • Page 14: Maintenance

    MAINTENANCE CLEANING OF THE pH AND REDOX ELECTRODES (mV) 1) Inorganic depostis and incrustations: Immerse the electrodes in a 3% hydrochloric acid for a period of 5 minutes to dissolve the deposits and incrustations. 2) Organic oil and grease film: Use a solution of water and detergent to wash the end of the electrode.

Table of Contents