Diagnostic Operation; How To Start; Mode Switch And Pad Status Display Check - Casio 200CR Service Manual

Table of Contents

Advertisement

4. Diagnostic operation

4-1. How to start

(1) Plug the power cord into an outlet.
(2) Execute the MAC operation.
(3) Turn the mode switch to "PRG" position.
(4) Input 99990000 and press the sub total button.
(5) Start the diagnostic program and issues the following receipt.
Note :
If you have done the registration after MAC operation, the Diagnostic program can not start.
XXXX N1N2N3
99990000

4-2. Mode switch and PAD status display check

When the Clear key is pressed or changing the position of mode switch, the machine displays the
mode switch position.
1
00-00-00
00-00
0001
XXXX : Version No.
N1 : 1 : Export (ADD:2)
2 : US
3 : Export (ADD:0)
5 : Canada
6 : Export (ADD:1)
N2 : Blank : Export
N3 : 0 : PCR-365
1 : PCR-360
Blank : Except Above model
PAD3 condition
0
Open
1
Short
PCR-360 (WHC) is displayed "0".
PCR-365 (OSS) is displayed "1".
PCR-460/240CR is displayed "0".
PAD2 condition
0
Open: US
1
Short: Canada
PAD1 condition
0
Open: US/Canada
1
Short: Except US/Canada
MODE SW position
1
PRG
2
RF
3
REG
4
CAL
5
X
6
Z
0
OFF
— 4 —