Download Print this page

Reactor / Partition Plate - Daikin RKS09JV2S Removal Procedure

2.0/2.2/2.5/2.8/3.5/3.6/4.2 kw class, 9000/12000/15000 btu/h class.

Advertisement

Reactor / Partition Plate

4. Reactor / Partition Plate
Warning
Step
1. Remove the reactor.
1
Remove the screw and
slide the reactor to the
left to unfasten the
hook.
2
Remove the reactor.
2. Remove the partition
plate.
1
Remove the 2 screws.
2
The partition plate has
2 hooks on the lower
side. Lift and pull the
partition plate and
remove it.
12
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Reactor
(R12611)
Partition plate
(R12613)
Hook
(R12614)
Si001353EB
Points
When reassembling, fit the 2
lower hooks into the bottom
frame.
Removal Procedure

Advertisement

loading