TCL TAC-07CHSA/XA71 Service Manual page 36

Wall mounted split-type air conditioners
Table of Contents

Advertisement

 
11.6 Compressor or outdoor fan does not operate at all.
 
 
 
 
Set the desired temperature of remote controller to be lower by 2°C or
 
over than room temperature, and start the cooling operation.
 
 
 
 
Does not operate at all.
 
 
 
 
 
Temperature sensor
 
 
 
 
 
(Contact & power)
 
 
 
Disconnection/short
 
 
 
 
 
 
Electric wire connection
 
check for outdoor side
 
 
 
 
Compressor & motor
 
 
 
 
Insulation resistance
 
 
Capacitor capacity
 
 
 
 
 
 
Air Conditioner Service Manual
Re-input after power off
open/short check
Connector check
circuit check of
connecting wire
detail check
Coil resistance
Compressor OLP
 
Repeat running/stopping
at a short time period.
Thermistor and evaporator
surface contact check.-
Clearance is needed (5mm).
Connector check
(Contact & power)
OLP/High pressure
switch/Low pressure
switch check
Operation mode
(dehumidifying) check
PCB assembly check
Check:
Temperature sensing circuit
Relay output
35