Figure 13 - Wiring Diagrams For Boilers With CG400 Probe Type Low Water Cut-Off
If any of the original wire as supplied with this appliance must be replaced, it must be replaced
with type 105°C Thermoplastic wire or its equivalent.

WIRING DIAGRAMS

24
Shown CG400
Terminals
PS802 To CG400
Cross Reference
PS802
CG400
N
2
H
1
C
P1
W
P2
B
A
P/N 1305004, Rev. E [8/31/2016]