TESTING THE SYSTEM

9. Testing the System

Periodic Test

The components of your security system are designed to be maintenance-free as much as possible.
Nevertheless, it is mandatory to test the system at least once a week and after an alarm event to verify that all
system sirens, detectors, keyfobs, keypads and other peripherals function properly. Proceed as described in this
section and if there is any problem, notify your installer at once.
The test is performed in three parts:
Siren Test: Each siren of the system is automatically activated for 3 seconds (outdoor sirens with low volume).
In addition, the system tests the siren of enrolled smoke sensors.
Temperature Sensor Test: When Temperature Sensors are enrolled in the system, the control panel displays
the temperature of each zone in Celsius or Fahrenheit.
Other Device Test: Each of the other devices in the system is activated by the user and the display indicates
which devices were not yet tested. The "it's me" indication helps to identify the untested devices if necessary.
A counter also indicates the number of devices that remain untested.
Carefully read the section titled "Additional Information" according to the indicated references
see table at end of this section.
A. To Enter the Periodic Test Menu
1.
READY 00:00
PERIODIC TEST
2.
ENTER CODE: 
CODE
3.
Go to step 4
B. To Test the Sirens
4.
SIRENS TEST
5.
SIREN N
6.
SIRENS TESTS END
or
C. To Display the Temperature
7.
TEMPERATURE TEST
8.
Z01 24.5C
54
Make sure the system is disarmed and then press the
repeatedly until the display reads "PERIODIC TEST" and press
The screen will now prompt you to enter your user code.
Enter your User Code.
The display now reads [SIRENS TEST].
To initiate the siren test press
all 4 LED's on the panel should light (LED test).
The display now reads [SIREN N], where "N" indicates the zone location
assigned to the siren that is currently being tested.
First the panel siren sounds for 3 seconds after which the WP Panel system
will automatically repeat the procedure for the next siren enrolled in the
system until all sirens are tested.
You should listen to the sirens sounds and make sure that all sirens sound.
Once all the sirens have been tested, the control panel will now test the
sirens of smoke sensors that are enrolled in the alarm system. The display
now reads [Zxx: SMOKE SIREN], where "Zxx" indicates the zone number of
the smoke sensor, and alternates with [<OK> TO CONTINUE]. During this
time, the siren of the tested smoke sensor will sound for up to one minute.
Press
to test the siren of the next smoke sensor.
When all the sirens test is complete, the display reads [SIREN TESTS END].
Press the
or the
the next step for zone temperature display.
The display now reads [TEMPERATURE TEST].
To display the temperature of zones on the control panel, press
The control panel reads the temperature of each zone. The display alternates
2 3
. Immediately after pressing
6
button to confirm the test and then move to
D-306232 WP8010/WP8030 V18 DSC EN USER
1
etc –
button
4
5
1
.
,
7
.