Testing The Relay For Continuity; Model Only); Replacing The Relay (Rm1350 Model Only) - Dometic DM2652 Service Manual

Table of Contents

Advertisement

Americana and New Generation Refrigerators

8.29 Testing the Relay for Continuity

(RM1350 Model Only)
29 Testing the Relay
Terminals
q
1. Perform the steps in "Replacing the Relay (RM1350
Model Only)" on page 43 to access the relay.
2. Attach the leads of the multi-meter to terminal 85 and
the chassis ground.
The reading should show no continuity. If it shows
continuity, it indicates a short to ground.
3. Attach the leads of the multi-meter to terminal 30 and
terminal 87.
The reading should show continuity. If it shows no
continuity, it indicates a faulty relay.
I
Consult the operating manual for the multi-meter
for specific device function.
EN
q
8.30 Replacing the Relay (RM1350

Model Only)

w
q
30 Removing the Relay from the Refrigerator
Relay
q
1. Disconnect the unit from all power sources (120 VAC
and 12 VDC).
2. Disconnect the wiring from the relay. Make note of
where the wires connect.
3. Remove the screw securing the relay to the
refrigerator wall.
4. Remove the defective relay.
5. Perform these steps in reverse with the new relay to
complete the replacement.
Service Procedures
Screw
w
43