Cooling Unit; Door Flapper (Rm1350 Model Only); Door Hinge - Dometic DM2652 Service Manual

Table of Contents

Advertisement

Americana and New Generation Refrigerators
Component
EN
Diagnostic Question

Cooling Unit

Is there a strong smell of ammonia?
Is a loud gurgling noise coming from the
cooling unit?
Is the refrigerator or freezer not cold
enough in any operating mode?
Is E3 displayed? (New Generation
models only)
Are two thermostat range setting lights
flashing? (First generation DMR702 and
DMR702-D models only)

Door Flapper (RM1350 Model Only)

Is the refrigerator or freezer not cold
enough in any operating mode?
Does condensation form in the fresh food
compartment or around the door frame?
Does the door not close properly?
Does the refrigerator rapidly build up
frost?
Does condensation form in the fresh food
compartment or around the door frame?
Does the door not close properly?
Action Based On Status
Replace the cooling unit.
1.
Bypass the cooling unit and test it for
blockage.
2. If the cooling unit fails the test, replace it.
1.
Inspect the flapper to confirm it closes
without an air gap.
2. Adjust the flapper guides or flapper as
needed.

Door Hinge

1.
Inspect each door hinge for warping or
other damage.
2. If damage is observed, replace the door
hinge.
Diagnostic Procedures