Reading The Alarms - Electrolux EWM09 Service Manual

Table of Contents

Advertisement

4.2

Reading the alarms

The last three alarms stored in the FLASH memory of the PCB can be displayed:
Enter the diagnostic mode.
Irrespective of the type of circuit board and configuration, turn the programme
selector knob clockwise to the tenth position and this will display the last alarm.
To display previous alarms, press the button to the left of the START/PAUSE
button in sequence (as shown in the figure).
To return to the last alarm, press the START/PAUSE button.
Technical Support - A.D.L. 02 / 2011
12/24
599 74 08-64