Precipitator
EEP 250 - 500
Service Manual

Advertisement

loading

Summary of Contents for eta EEP 250

  • Page 1 2019-04-05 0000000368 V.006 X.45.0 93532-004 Precipitator EEP 250 - 500 Service Manual...
  • Page 2 ETA Heiztechnik Gewerbepark 1 A-4716 Hofkirchen an der Trattnach Tel: +43 (0) 7734 / 22 88 -0 Fax: +43 (0) 7734 / 22 88 -22 info@eta.co.at www.eta.co.at...
  • Page 3: General Information

    "www.eta.co.at". Copyright All contents of this document are property of ETA Heiztechnik GmbH and are protected by copyright. Any reproduction, transfer to third parties or use for other purposes is prohibited without written permission...
  • Page 4: Maintenance Notes

    We recommend cleaning the precipitator and emptying the ash bins before an emission measurement is made. Use adhesive to affix the seals, for example. Explanation of pictograms Only blow out the components with your mouth. Switch the boiler on/off with the mains switch. www.eta.co.at...
  • Page 5 No water or moisture in this area. No leaks in the components, for example, screw connection or maintenance cover. Technical illustrations The technical illustrations show the cleaning and maintenance of the EEP 333-500 precipitator; these steps are also valid for the EEP 250 precipitator.
  • Page 6 Drive and position switch for the flaps in the bypass Maintenance covers for the flaps in the bypass. Maintenance cover for the precipitator Drive and position switch for the electrode dedusting Flushing air fan Drive and position switch for the sliding rake www.eta.co.at...
  • Page 7: Maintenance Table

    Cleaning and maintenance Maintenance table Maintenance table Cleaning must be carried out at least once a year or when requested by the control system. Maintenance is necessary at least every 2 years or when requested by the control system. We recommend you perform maintenance annually.
  • Page 8: Regular Maintenance

    320 litres. The steps are essentially the same for all other available ash bins (e.g.: 240 -litre). Empty the ash bin Open the screw cap on the connection unit and hang it in the parking position. Fig. 2-1: Connection unit www.eta.co.at...
  • Page 9 Cleaning and maintenance Regular maintenance Actuate the locking lever so the bottom folds out. Do Then fasten the floor of the ash bin again with the not let the bottom strike anything or become bent, so locking lever. Make sure the lever engages properly. that the seal on the bottom fits evenly.
  • Page 10  Only clean out the piping with an ash vacuum. Never sweep ash into the precipitator as this can block the precipitator's exhaust path. As a result, the boiler can no longer ignite and this can lead to deflagrations. www.eta.co.at...
  • Page 11 Cleaning and maintenance Cleaning (customer) Re-attach the maintenance cover to the piping. 2.5.3 Clean precipitator Remove maintenance cover and panels Remove the panel next to the flue gas connections. Fig. 2-9: Maintenance cover Fig. 2-10: Panel Remove the panel from the top and remove the insulating cover.
  • Page 12 Fig. 2-14: Clean the inner walls Fig. 2-16: Flushing air opening on the isolator Do not clean the opening with compressed air, because this will stir up the ash, which can end up in the precipitator control system and cause damage. www.eta.co.at...
  • Page 13 If cracks or small holes can be replace if necessary. "felt" there is damage. In this case, contact ETA Customer Support. Check the alignment of the electrodes The electrodes must be in the centre of the precipitator so that the flue gas can be optimally cleaned.
  • Page 14 Switch the boiler back on with the On/Off switch. Fig. 2-21: Maintenance cover Finally, place the insulating cover and re-attach the panels. Fig. 2-22: Panels and insulating cover Re-install the panel next to the flue gas connections. Fig. 2-23: Panel www.eta.co.at...
  • Page 15 Cleaning and maintenance Maintenance (expert) Maintenance (expert) 2.6.2 Check flaps 2.6.1 Preparation Removing the panels Remove the panel over the drive of the flaps. Before this maintenance, perform all steps for the preceding maintenance intervals Before this maintenance, all steps for the preceding maintenance intervals...
  • Page 16 Inspect the integrity of the seals on the flaps and replace if necessary. If cracks or other flaws are noticeable, they must be replaced. Fig. 2-27: Position of the flaps during operation Fig. 2-30: Check the seals on the flaps www.eta.co.at...
  • Page 17 Cleaning and maintenance Maintenance (expert) Installing the panels Re-install the panel over the drive of the flaps. Fig. 2-31: Seals Inspect the seals on the maintenance covers to ensure Fig. 2-34: Panel they are in good order and replace if necessary. Then re-install the maintenance covers.
  • Page 18 Lubricate the drive chain with chain spray. Fig. 2-36: Panels and insulating cover Remove both maintenance covers. Fig. 2-39: Electrode dedusting drive chain Check whether the position switch is actuated. Fig. 2-37: Maintenance cover Fig. 2-40: Position switch www.eta.co.at...
  • Page 19 Cleaning and maintenance Maintenance (expert) Check idle position of the electrode dedusting Checking the ease of movement of the striking mechanisms A screw is located on the electrode dedusting drive wheel which actuates the position switch for the idle Check the ease of movement of all striking position of the electrode dedusting.
  • Page 20 Lubricate the drive chains with chain spray. located behind these. Fig. 2-47: Drive chain of the sliding rakes Fig. 2-45: Panel Fig. 2-48: Drive chain of the sliding rakes Fig. 2-46: Panel Check whether the position switches are actuated. Fig. 2-49: Position switch www.eta.co.at...
  • Page 21 Cleaning and maintenance Maintenance (expert) Installing the panels Reinstall the panels on both sides on the bottom of the precipitator. Fig. 2-50: Position switch Check the idle position of the sliding rakes A screw is located on every sliding rake drive wheel Fig.
  • Page 22 Fig. 2-56: Maintenance cover CAUTION! Avoid operation with damaged seals Never operate the precipitator with damaged seals. Otherwise, leak air is sucked in, disturbing the combustion process and causing increased wear.  Always replace seals immediately when they are damaged. www.eta.co.at...
  • Page 23 Cleaning and maintenance Maintenance (expert) Re-attaching the maintenance cover and panels Checking the position switches for the ash bins Place both maintenance covers and tighten the screws Check the function of the ash bin position switch. The evenly and cross-wise. switch must be actuated when locking the screw cap.
  • Page 24 Establish operational readiness Switch the boiler on via the mains switch and start de-ashing Restore the boiler's power supply from the mains switch. Start de-ashing, so that the boiler can perform de-ashing. Switch the boiler back on with the On/Off switch. www.eta.co.at...
  • Page 25 Cleaning and maintenance Maintenance (expert)
  • Page 26 Clean the precipitator • Check and remove ash accumulations • Clean the flushing air opening • Clean and inspect the electrode holder • Check the alignment of the electrodes • Check maintenance cover seal performed on: _________________________ performed by: _________________________ Comments: www.eta.co.at...
  • Page 27 Records Maintenance (expert) Maintenance (expert) Maintenance is required at least every 2 years or when requested by the control system. We recommend you perform maintenance annually. Tasks Notes Emptying ash bin • Emptying ash bin • Check the seals Clean the piping •...
  • Page 28 Clean the precipitator • Check and remove ash accumulations • Clean the flushing air opening • Clean and inspect the electrode holder • Check the alignment of the electrodes • Check maintenance cover seal performed on: _________________________ performed by: _________________________ Comments: www.eta.co.at...
  • Page 29 Records Maintenance (expert) Maintenance (expert) Maintenance is required at least every 2 years or when requested by the control system. We recommend you perform maintenance annually. Tasks Notes Emptying ash bin • Emptying ash bin • Check the seals Clean the piping •...
  • Page 30 Clean the precipitator • Check and remove ash accumulations • Clean the flushing air opening • Clean and inspect the electrode holder • Check the alignment of the electrodes • Check maintenance cover seal performed on: _________________________ performed by: _________________________ Comments: www.eta.co.at...
  • Page 31 Records Maintenance (expert) Maintenance (expert) Maintenance is required at least every 2 years or when requested by the control system. We recommend you perform maintenance annually. Tasks Notes Emptying ash bin • Emptying ash bin • Check the seals Clean the piping •...
  • Page 32 Clean the precipitator • Check and remove ash accumulations • Clean the flushing air opening • Clean and inspect the electrode holder • Check the alignment of the electrodes • Check maintenance cover seal performed on: _________________________ performed by: _________________________ Comments: www.eta.co.at...
  • Page 33 Records Maintenance (expert) Maintenance (expert) Maintenance is required at least every 2 years or when requested by the control system. We recommend you perform maintenance annually. Tasks Notes Emptying ash bin • Emptying ash bin • Check the seals Clean the piping •...
  • Page 34 Clean the precipitator • Check and remove ash accumulations • Clean the flushing air opening • Clean and inspect the electrode holder • Check the alignment of the electrodes • Check maintenance cover seal performed on: _________________________ performed by: _________________________ Comments: www.eta.co.at...
  • Page 35 Records Maintenance (expert) 3.10 Maintenance (expert) Maintenance is required at least every 2 years or when requested by the control system. We recommend you perform maintenance annually. Tasks Notes Emptying ash bin • Emptying ash bin • Check the seals Clean the piping •...
  • Page 36 Clean the precipitator • Check and remove ash accumulations • Clean the flushing air opening • Clean and inspect the electrode holder • Check the alignment of the electrodes • Check maintenance cover seal performed on: _________________________ performed by: _________________________ Comments: www.eta.co.at...
  • Page 37 Records Maintenance (expert) 3.12 Maintenance (expert) Maintenance is required at least every 2 years or when requested by the control system. We recommend you perform maintenance annually. Tasks Notes Emptying ash bin • Emptying ash bin • Check the seals Clean the piping •...
  • Page 38 Clean the precipitator • Check and remove ash accumulations • Clean the flushing air opening • Clean and inspect the electrode holder • Check the alignment of the electrodes • Check maintenance cover seal performed on: _________________________ performed by: _________________________ Comments: www.eta.co.at...
  • Page 39 Records Maintenance (expert) 3.14 Maintenance (expert) Maintenance is required at least every 2 years or when requested by the control system. We recommend you perform maintenance annually. Tasks Notes Emptying ash bin • Emptying ash bin • Check the seals Clean the piping •...