Control Panel Features
Heat Mode Indicator Light
Swing
Timer
Button
Button
Swing Button
Used to initiate the Auto Swing feature. When the
operation is ON, pressing the SWING button can
stop the louver at the desired angle.
Timer button
Used to initiate the AUTO ON start time and AUTO OFF
stop time program, in conjuction with the Up ( )
and Down ( ) buttons. The timer on or off light will
illuminate depending on the selected setting.
Fan button
Controls the fan speed. Press to control the fan speed
in four steps - LOW, MID, HIGH and AUTO. The selected
fan speed light (except AUTO) will illuminate. When
AUTO is selected, no lights will illuminate.
Mode button
Selects the desired operating mode. Each time you
press the button, a mode is selected in a sequence
that goes from AUTO, COOL, DRY, FAN and HEAT
(cooling only models excluded). The mode light
illuminates and indicates the selected mode.
Up (
) and Down (
Used to adjust (increasing/decreasing) temperature
settings in 1°C/1°F(or 2°F) increments in a range of
17°C/62°F to 30°C/86°F or the TIMER setting in a range
of 0 ~ 24hrs.
NOTE
The control is capable of displaying temperature in
degrees Fahrenheit or degrees Celsius. To convert
from one to the other, press and hold the Up and
Down buttons at the same time for 3 seconds.
Page 6
Follow Me
Mode
Up ( ) and Down ( )
Button
Buttons
) buttons
LED Display
Fan
Button
Power button
Power switch on/off.
Sleep button
Used to initiate the SLEEP operation.
LED display
Shows the set temperature in °C (Degrees
Celsius) or °F (Degrees Fahrenheit) and the
Auto-timer settings. While on DRY and FAN
modes, it shows the room temperature.
Shows Error codes and protection code:
E1 - Room temperature sensor error.
E2 - Evaporator temperature sensor error.
E3 - Condenser temperature sensor error
(select models).
E4 - Display panel communication error.
P1 - Bottom tray is full - Connect the drain
hose and drain the collected water
away. If protection code repeats, call
for service.
NOTE
When one of the above malfunctions
occurs, turn off the unit and check for
any obstructions. Restart the Unit. If the
malfunction persists, turn off the unit
and unplug the power cord. Contact the
manufacturer or its service agents or a
similar qualifi ed person for service.
Sleep
Power
Button
Button
User Manual

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Rac-pd0811cruRac-pd1211cruRac-pd1412cruRac-pd1412hru