Daikin FTYNV20AV1 Owner's Manual page 14

R410a split series
Table of Contents

Advertisement

Installation of indoor unit
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from the
front side.
3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw
and then fix the power connection wire
with wire clip.
Note: the wiring board is for reference only,
please refer to the actual one.
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.
● If the length of power connection wire is insufficient (see table below), please
contact the supplier for a new one. Avoid extending the wire by yourself.
● A circuit breaker must be installed for the air conditioner in serial connection.
wiring board
grounding
wire
N
( 1 )
2
3
wire clip
Class:
Length of Connecting Wire (mm)
20
25
35
50
60
cable-
cross hole
power connection
wire
Outdoor unit connection
(for reference)
N(1) 2
blue black brown
1800
1800
2000
2000
2000
10
3
yellow-
green

Advertisement

Table of Contents
loading

Table of Contents