Link RLC-2 Manual page 92

Table of Contents

Advertisement

Daily Programming Example:
During the day your repeater is overcome by interference that makes COR access impossible. This
interference usually begins at 6:00 AM and does not quiet down until about 7:00 PM. During these hours,
the repeater needs to be in PL and COR access mode. The owner has previously set up a macro that changes
the courtesy beep and forces the repeater into PL and COR access. This event is assigned to Macro #3
(C183). Normal courtesy beep and COR access is assigned to Macro #4 (C184). Using the daily scheduler,
the repeater owner will assign Macro #3 and Macro #4 to be executed by the controller as scheduler events
01 and 02. Note that by default, Command C061 is password protected with password P0 (96). You want
macro #3 message to only go out the main port.
To set PL and COR access to the repeater:
96 C061 * 01 2 1 0600 0 C183 <Unkey or *>
Voice Response: S 01 ON D8 AT 0600 A C183
S 01 Event Chosen
ON Event Enabled
D8 Occurs Every Day
0600 Time the Event Occurs
A Occurs at AM
C183 Command to be Executed
To set COR access to the Repeater:
96 C061 * 02 2 1 0700 1 C184 <Unkey or *>
Voice Response: S 02 ON D8 AT 0700 P C184
S 02 Event Chosen
ON Event Enabled
D8 Occurs Every Day
0700 Time the Event Occurs
P Occurs at PM
C184 Command to be Executed
Copyright 1995 Link Communications Inc.