12
Serial Echo allows all data that is sent to the RLC-2 to be echoed out back to the sending source.
Parameters: @
1 - On
0 - Off
Baud rate can be changed to: 300,600,1200,2400,4800,9600 Baud
Parameters: #
0 - 9600
1 - 4800
2 - 2400
3 - 1200
4 - 600
5 - 300
Log-On Control is used when radio connection is used. The log-on should be used if security is needed for
control over the serial port. When using a serial terminal, or a computer, the log-on can be shut-off.
Parameters: $
1 - On
0 - Off
Internal Echo Control is used to enable/disable the controllers internal responses over the serial port. The
function is normally used for Link Communications use. This function is normally 'Off'
Parameters: %
1 - Enabled internal echo
0 - Disables internal echo
Serial Format: [S15 @ # $ %]
S99 - Serial System Log OFF
This command logs the serial server off the RLC-2 Controller. The Serial Port Log-Off Message will appear
when you Log-Off. If you do not Log-Off, the RLC-2 will automatically Log-Off after 1 Minute of Non-
Activity.
"RLC-2 REPEATER AND LINK CONTROLLER: LOG OFF"
Copyright 1995 Link Communications Inc.