Cansec H1000 Installation Manual

Elevator control

Advertisement

Quick Links

H1000 Elevator Control
INSTALLATION GUIDE
For use with H1000 V1.1 panel and daughter card EX100 V1.1
October 2015

Advertisement

Table of Contents
loading

Summary of Contents for Cansec H1000

  • Page 1 H1000 Elevator Control INSTALLATION GUIDE For use with H1000 V1.1 panel and daughter card EX100 V1.1 October 2015...
  • Page 2: Table Of Contents

    Using AIR-485 (RS-485)..........................18 Wiegand-Compatible Reader Wiring ........................19 Appendix ................................. 20  Using a CLAUSB2 (RS-485) .......................... 20 © Copyright 2014 - 2015 Cansec Systems, Ltd. H1000 Elevator Control Page 2 of 20 Installation Guide October 2015 • Rev. 1.7...
  • Page 3: Introduction

    Introduction The H1000 controller has been designed to handle access to 64 floors of elevator control. In the elevator application, the credential owners simply present their credentials to the reader mounted inside the elevator cab to gain access to their assigned floors. This prevents access to unauthorized elevator floors and at the same time allows the building owner to isolate different organizations that cohabit the same building.
  • Page 4: Overview

    The Elevator Relay Interface Box must be supplied by the elevator contractor. 12 volt relays are to be used in the interface box. The H1000 output relay contacts will switch the 12 volt coil of the relay in the interface box.
  • Page 5: Elevator Control Configurations And Wirings

    Elevator Control Configurations and Wirings 16 FLOOR ELEVATOR SYSTEM This configuration is used when connecting to an elevator system of up to 16 floors. This consists of one H1000 control panel. Dipswitch Settings: OPT1: ON OPT2: OFF OPT3: OFF OPT4: OFF Panel address is set to 1 in this example.
  • Page 6: Floor Elevator System

    32 FLOOR ELEVATOR SYSTEM This configuration is used when connecting to an elevator system of up to 32 floors. This consists of two H1000 control panels, designated as a master panel and a slave panel. RS485 Communication wires to host computer using Cansec communication line driver, e.g.
  • Page 7: Floor Elevator System

    48 FLOOR ELEVATOR SYSTEM This configuration is used when connecting to an elevator of up to 48 floors. This consists of three H1000 control panels, designated as a master panel and a two slave panels. RS485 Communication wires to host computer using Cansec communication line driver e.g.
  • Page 8 Panel address is set to the same as Master Panel See Hurricane Operator Guide for more information.  Edit->Panel Definitions. Select 32, 48, 64 Elevator Floor Board. H1000 Elevator Control Page 8 of 20 Installation Guide October 2015 • Rev. 1.7...
  • Page 9: Floor Elevator System

    64 FLOOR ELEVATOR SYSTEM This configuration is used when connecting to an elevator of up to 64 floors. This consists of four H1000 control panels, designated as a master panel and three slave panels. RS485 Communication wires to host computer using Cansec communication line driver, e.g.
  • Page 10 Panel address is set to the same as Master Panel See Hurricane Operator Guide for more information.  Edit->Panel Definitions. Select 32, 48, 64 Floor Elevator Board. H1000 Elevator Control Page 10 of 20 Installation Guide October 2015 • Rev. 1.7...
  • Page 11: Master And Slave Control Panel Led Indicators

    Slave H1000 control panels. There are LEDs associated with this communication channel, which are described below. All H1000 panels have 16 output relays, and each of these relays have an associated relay LED which will illuminate when the relay is activated. These LEDs are labeled OLED1 to OLED16.
  • Page 12: Master Panel Communication Leds

    RS485 Host Communication  Master EX100 Communication LEDs If the Master H1000 panel has been correctly configured as a 32 to 64 floor elevator system, the two LEDs on the EX100 daughter board will indicate the RS485 communication to the Slave H1000 control panels. The EX100 LEDs are labeled TX485 (Green LED1) and RX485 (Red LED2).
  • Page 13: Slave Panel Communication Leds

    The slave EX100 RS485 communications are indicated by RX485 - LED1 and TX485 - LED2. The green TX RS485 LED will only toggle when the address of the Slave H1000 is sent from the Master H1000 control panel. When the Slave H1000 receives this poll it will send the response to the Master H1000 panel.
  • Page 14: Connection To The Elevator Controls

    H1000 outputs. It is important to understand that the H1000 panel’s output relays (“Form C”) will be controlling the coils of the relays in the interface box and that a single shielded single pair must be used for each relay connection.
  • Page 15: Host Communication Wiring

    The 2-wire RS-485 connections are A and B. The shield wire should be connected to GND. RS-485 Communication Port (H1000 Version 1.1) H1000 Version 1.0 controllers are equipped with one RS485 connector. Two wires have to be connected into one connector for the next added panel.
  • Page 16: Using A Clausb (Rs-485)

    USING A CLAUSB (RS-485) For CLAUSB2, please see Appendix. Communication Wiring Using a CLAUSB H1000 Elevator Control Page 16 of 20 Installation Guide October 2015 • Rev. 1.7...
  • Page 17: Using A Canlan (Rs-485)

    NOTE: It’s recommended to use Option 2 below and connect to a battery backup power source to avoid communication failure when there is a power outage. Communication Wiring Using a CanLan H1000 Elevator Control Page 17 of 20 Installation Guide...
  • Page 18: Using Air-485 (Rs-485)

    Air-485. It is recommended that the Air-485 modems are connected to a battery backup power source to avoid communication failure during a power outage. Communication Wiring Using an Air-485 H1000 Elevator Control Page 18 of 20 Installation Guide October 2015 • Rev. 1.7...
  • Page 19: Wiegand-Compatible Reader Wiring

    Wiegand-Compatible Reader Wiring The elevator reader, which is mounted in the elevator cab, can read a standard 26-bit or Cansec 37-bit Wiegand proprietary format card or the HID Corporate 1000 format card. The H1000 uses a small 6 pin keyed connector to terminate the reader wiring.
  • Page 20: Appendix

    Appendix USING A CLAUSB2 (RS-485) Communication Wiring Using a CLAUSB2 H1000 Elevator Control Page 20 of 20 Installation Guide October 2015 • Rev. 1.7...