1-10. Pinch Solenoid Replacement

CHART B
Model Type
TYPE A
Connector (A)
P20
P.C.Board (B)
MECH
I/F
(Removal)
1. Disconnect the connector (A) on the P.C.Board
(B). (Refer to above chart)
2. Unscrew the 2 screws (A) and remove the Pinch
Solenoid Unit as shown in Figure 1-10.
3. Unscrew the 2 screws (B) and remove the Pinch
Solenoid Angle as shown in Figure 1-10.
4. Unscrew the 2 screws (C) and remove the Pinch
Solenoid from the Pinch Solenoid Base.
(Installation)
1.
Install the new Pinch Solenoid follow the removal
steps in reverse order.
2.
After installation, execute the Pinch Solenoid
Position Adjustment.
Figure 1-10
TYPE B
TYPE
C,D
P2020
P610
SERVO
SERVO
3-10
1-11. Pinch Solenoid Position
Adjustment
SPEC.
T = 0.3 mm
TEST
Gap T
ADJUST
Screw (A) and Hole (B)
MODE
EJECT (Power OFF)
TOOL
Eccentric Driver (VFK0357)
1. Confirm the power of condition at VTR turn to
OFF.
2. Push the pinch roller by hand to be close to
capstan.
3. Push the pinch solenoid by hand so that the
pinch roller contacts capstan.
4. Loosen the two screws (A) and adjust the hole
(B) by VFK0357 so that gap (T) is within
specification.
5. The position for confirm Gap, which is located
spring scratch to Plate (C) side.
Figure 1-11