1. Set the adjustment mode. (Refer to [LISTA Adjustment Modes] of the "Table of Test Point".)
2. Playback the LISTA Alignment Tape.
3. Select the item "<1> Sensitivity Measurement" on the LISTA main menu, and then appeared "1.2% Speed. . ."
on the screen, press the Enter key, and then start measurement of the sensitivity value.
4. Confirm the sensitivity value is within specification, when the message <<Sensitivity Measurement Finish>>
and "Sensitivity = Sensitivity Value" are displayed on screen.
5. If it is out of specification, repeat the step item 3 and 4.
6. If still out of specification, execute the "Sensitivity Adjustment" again.