S&T kontron KSwitch D3 User Manual

S&T kontron KSwitch D3 User Manual

Unmanaged fast ethernet switch
Table of Contents

Advertisement

Quick Links

USER GUIDE
KSwitch D3 Unmanaged Fast Ethernet
Switch
Doc. Preliminary User Guide, Rev. 0.9
Doc. ID: 1068-1422
www.kontron.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the kontron KSwitch D3 and is the answer not in the manual?

Questions and answers

Summary of Contents for S&T kontron KSwitch D3

  • Page 1  USER GUIDE KSwitch D3 Unmanaged Fast Ethernet Switch Doc. Preliminary User Guide, Rev. 0.9 Doc. ID: 1068-1422 www.kontron.com...
  • Page 2 KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 This page has been intentionally left blank www.kontron.com // 2...
  • Page 3 KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 KSWITCH D3 UNMANAGED FAST ETHERNET SWITCH – USER  GUIDE Disclaimer Kontron would like to point out that the information contained in this user guide may be subject to alteration, particularly as a result of the constant upgrading of Kontron products.
  • Page 4 KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 Intended Use THIS DEVICE AND ASSOCIATED SOFTWARE ARE NOT DESIGNED, MANUFACTURED OR INTENDED FOR USE OR RESALE FOR THE OPERATION OF NUCLEAR FACILITIES, THE NAVIGATION, CONTROL OR COMMUNICATION SYSTEMS FOR AIRCRAFT OR OTHER TRANSPORTATION, AIR TRAFFIC CONTROL, LIFE SUPPORT OR LIFE SUSTAINING APPLICATIONS, WEAPONS SYSTEMS, OR ANY OTHER APPLICATION IN A HAZARDOUS ENVIRONMENT, OR REQUIRING FAIL-SAFE PERFORMANCE, OR IN WHICH THE FAILURE OF PRODUCTS COULD LEAD DIRECTLY TO DEATH, PERSONAL INJURY, OR SEVERE PHYSICAL OR...
  • Page 5 KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 Revision History Revision Brief Description of Changes Date of Issue Author/ Editor Preliminary version 2021-April-21 Terms and Conditions Kontron warrants products in accordance with defined regional warranty periods. For more information about warranty compliance and conformity, and the warranty period in your region, visit http://www.kontron.com/terms- and-conditions.
  • Page 6: Symbols

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 Symbols The following symbols may be used in this user guide DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 7: For Your Safety

    KSwitch D3 Unmanaged Fast Ethernet Switch – Preliminary User Guide, Rev. 0.9 For Your Safety Your new Kontron product was developed and tested carefully to provide all features necessary to ensure its compliance with electrical safety requirements. It was also designed for a long fault-free life. However, the life expectancy of your product can be drastically reduced by improper treatment during unpacking and installation.
  • Page 8: Special Handling And Unpacking Instruction

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 Special Handling and Unpacking Instruction ESD Sensitive Device! Electronic boards and their components are sensitive to static electricity. Therefore, care must be taken during all handling operations and inspections of this product, in order to ensure product integrity at all times.
  • Page 9: Quality And Environmental Management

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 Quality and Environmental Management Kontron aims to deliver reliable high-end products designed and built for quality, and aims to complying with environmental laws, regulations, and other environmentally oriented requirements. For more information regarding Kontron’s quality and environmental responsibilities, visit http://www.kontron.com/about-kontron/corporate- responsibility/quality-management.
  • Page 10: Table Of Contents

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 Table of Contents Symbols ..........................................6 For Your Safety ........................................7 High Voltage Safety Instructions .................................. 7 Optical Safety Instructions ....................................7 Special Handling and Unpacking Instruction ............................8 Lithium Battery Precautions ..................................
  • Page 11: List Of Tables

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 7.4. Mechanical Specification ..................................32 7.5. Power Specification ....................................34 Maintenance ....................................... 35 Technical Support ..................................... 36 9.1. Returning Defective Merchandise ..............................36 Warranty ......................................37 10.1. Limitation/Exemption from Warranty Obligation ........................37 List of Acronyms ......................................
  • Page 12: 1/ Introduction

    1/ Introduction This user guide focuses on describing the special features of the Kontron KSwitch D3 UF Unmanaged Fast Industrial Switch series referred to as switch within this user guide. To ensure you have the latest version of this user guide, visit Kontron’s KSwitch Industrial Ethernet Switches, at https://www.kontron.com/products/systems/ethernet-...
  • Page 13: 2/ General Safety Instructions

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 2/ General Safety Instructions Please read this passage carefully and take careful note of the instructions, which have been compiled for your safety and to ensure to apply in accordance with intended regulations. If the following general safety instructions are not observed, it could lead to injuries to the operator and/or damage of the product;...
  • Page 14: Laser

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9  a suitable, easily accessible disconnecting device is used in the application (e.g. overcurrent protective device), if the product itself is not disconnectable  a disconnect device, if provided in or as part of the product, shall disconnect both poles simultaneously ...
  • Page 15: 3/ Shipment And Packaging

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 3/ Shipment and Packaging 3.1. Packaging All parts are delivered together in a switch specific cardboard package designed to provide adequate protection to absorb shock. Kontron recommends keeping the packaging to store or transport the switch. 3.2.
  • Page 16 KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 Product Name / Product Group Description RK4U 19” Rack Mount Kit 4U Enables DIN-Rail Switch to be installed in a 4U rack WK25 Wall Mount kit 2x wall mount plates and screws SFP Modules EN-SFP-F-M002-T 100 Megabit SFP Modules...
  • Page 17: Product Identification Type Label

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 3.5. Product Identification Type Label Figure 1: KSwitch Type Label Model full name Production date Series name Electrical Specification Part Number(PN) with bar code QI code Revision Certification Information Serial Number (SN) with barcode www.kontron.com // 17...
  • Page 18: 4/ Features

    The Kontron KSwitch D3 UF unmanaged industrial Ethernet switch with up to 24 fast Ethernet ports providing easy to use plug-n-play connectivity. Copper and fiber optics ports are available.
  • Page 19: Faceplate Features

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 4.1. Faceplate Features 4.1.1. RJ45 Copper Ethernet Ports To connect to a PC use a straight-through or a cross-over Ethernet cable and when connecting to an Ethernet device use UTP (Unshielded Twisted Pair) or STP (Shielded Twisted Pair) Ethernet cables.
  • Page 20: Sfp Fiber Ethernet Ports

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 4.1.2. SFP Fiber Ethernet Ports Up to two 100 Base fiber SFP slots are available on the 10-port variant. For each fiber port there is a transmit (TX) and receive (RX) signal. When making fiber optic connections ensure that the transmit (TX) port of the switch connects to the receive (RX) port of the other device, and the receive (RX) port of the switch connects to the transmit (TX) port of the other device.
  • Page 21: Indicator Leds (P1, P2, Alm And Ethernet)

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 4.1.3. Indicator LEDs (P1, P2, ALM and Ethernet) The indicator LEDs show the normal operation of the switch and in the case of failure may be used for faultfinding. The indicator LEDs are contained within the copper RJ45 connectors, as separate Link/Activity LEDs or as power/alarm indicator LEDs.
  • Page 22: Dc Terminal Block (16-Port)

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 4.1.4. DC Terminal Block (16-port) The switch can be powered from dual external DC power supplies (input range of 12 VDC to 58 VDC) by inserting the positive and negative wires into the corresponding contacts for the first power supply (P1+/-) and second power supply (P2+/-) on the DC terminal block and tighten the wire-clamp screws to prevent the wires from loosening.
  • Page 23: Dc Terminal Block Alarm Relay Contacts (16-Port)

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 4.1.5. DC Terminal Block Alarm Relay Contacts (16-port) The alarm relay contacts, in the middle of the DC terminal block connector, detect an Ethernet port failure and forms a short circuit.
  • Page 24: Bottom Side Features

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 4.2. Bottom Side Features For the 10-port switch, the DC terminal block and the ground connector are located on the bottom side. 4.2.1. DC Terminal Block Power Contacts (10-port) The switch can be powered from dual external DC power supplies (input range of 12 VDC to 58 VDC) by insert the positive and negative wires into the corresponding contacts for the first power supply P1+/- and second power supply P2+/- on the DC terminal block and tighten the wire-clamp screws to prevent the wires from loosening.
  • Page 25: Dc Terminal Block Alarm Relay Contacts (10-Port)

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 4.2.2. DC Terminal Block Alarm Relay Contacts (10-port) The alarm relay contacts, in the middle of the DC terminal block connector, detect an Ethernet port failure and forms a short circuit.
  • Page 26: Ground Connector (10-Port)

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 4.2.3. Ground Connector (10-port) The switch must be grounded properly using the ground connector, for optimum system performance. Figure 11: Ground Connector (10-port) Ground properly using a ground that meets the ground requirements specified in your local, national and international region.
  • Page 27: Rear Side Features

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 4.3. Rear Side Features The mounting holes for the DIN-Rail clip enable the orientation of the DIN-Rail clip to be changed by 180°. Sets of mounting holes on the top and bottom (10-port) and left and right (16-port) on the rear side, enable installation of the wall mount plates.
  • Page 28: 5/ Mounting

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 5/ Mounting Before mounting the switch, consider the required orientation of the switch within the installation environment and access to connectors. Mount leaving a clearance of 20 mm around the switch, to ensure proper operation and to prevent the switch from overheating.
  • Page 29: Wall Mounting

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 5.3. Wall Mounting To mount on a flat surface or wall use the Wall Mount Kit, see Table 2: List of Accessories. The number of wall mount plates required to mount the switch and the position of the wall mount plates on the rear side of the switch, depends on the switch’s port variant.
  • Page 30: 6/ Starting Up

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 6/ Starting Up Before connecting the switch to power and starting up, read and observe the instructions within this user guide including Chapter 2/: General Safety Instructions. The switch supports dual power inputs with an input range of 12 VDC to 58 VDC, on the power contacts P1+/- and P2+/- on the DC terminal block.
  • Page 31: 7/ Technical Specification

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 7/ Technical Specification The KSwitch D3 UF series of Unmanaged Fast Ethernet Switches supports 10-port and 16-port variants, and on request a 24-port variant. 7.1. Hardware Specification Table 6: Hardware Specification 10-Port 16-Port 24-Port (on-request)
  • Page 32: Environmental Specification

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 7.2. Environmental Specification Table 7: Environmental Specification Environmental 10-port 16-port 24-Port (on-request) Operating Temperature -40 to +75°C (cold startup at -40°C) Storage Temperature -40 to +85°C Humidity 5% to 95% RH (non-condensing) 7.3.
  • Page 33: Figure 16: Mechanical Dimensions 16-Port

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 Figure 16: Mechanical Dimensions 16-port www.kontron.com // 33...
  • Page 34: Power Specification

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 7.5. Power Specification The switch supports dual external DC power supplies. The external DC power supplies used must fulfill the specified electrical ratings in this user guide and comply with the safety requirements of UL/IEC 62368-1. Table 10: Electrical Specification Power 10-port...
  • Page 35: 8/ Maintenance

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 8/ Maintenance The switch contains no user serviceable parts. Maintenance or repair on the switch may only be carried out by qualified personnel authorized by Kontron. Return the switch to Kontron for maintenance and repair, see Chapter 9.1: Returning Defective Merchandise. The switch contains no user serviceable parts.
  • Page 36: 9/ Technical Support

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 9/ Technical Support For technical support contact our Support Department:  E-mail: support@kontron.com  Phone: +49-821-4086-888 Make sure you have the following information available when you call:  Product ID Number (PN), ...
  • Page 37: 10/ Warranty

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 Warranty Kontron defines product warranty in accordance with regional warranty definitions. Claims are at Kontron’s discretion and limited to the defect being of a material nature. To find out more about the warranty conditions and the defined warranty period for your region, following the steps below: Visit Kontron’s Term and Conditions webpage.
  • Page 38: List Of Acronyms

    KSwitch D3 Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9 List of Acronyms Table 11: List of Acronyms Alternating Current Network Time Protocol Access Control List Powered Device BPDU Bridge Protocol Data Unit Part Number Code of Federal Regulations Power over Ethernet Direct Current Power Source 2...
  • Page 39: About Kontron

    KSwitch D3 Unmanaged Fast Ethernet Switch – Preliminary User Guide, Rev. 0.9 About Kontron Kontron is a global leader in IoT/Embedded Computing Technology (ECT). As a part of technology group S&T, Kontron, together with its sister company S&T Technologies, offers a combined portfolio of secure hardware, middleware and services for Internet of Things (IoT) and Industry 4.0 applications.