Lincoln Electric Prism L17587-1 Operator's Manual page 51

Table of Contents

Advertisement

®
PRISM
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
Poor suction.
Dust or smoke coming out of the
outlet opening(s). Pollution of the
facility.
Dust or smoke coming out of the
inlet opening(s). Pollution of the
facility.
Alarm - Red Alarm LED lights.
Fan does not start running
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
CAUSE
FUNCTION PROBLEMS
1. Outlet(s) are blocked.
2. Filter cartridge is clogged.
1. Filter cartridge is damaged.
2. Sealing on lter cartridge is
damaged.
1. Outlets blocked.
2. Filter cartridge clogged.
3. Non- - return valve(s) installed
incorrectly.
1. Red alarm light is on solid if
controls know there is a fault with the
VFD.
2. Red alarm light is ashing if the DP
alarm set point is reached.
No power
Variable Speed Drive has faulted and
has red fault light on or shows no
lights at all.
Motor defective
Controller defective
RECOMMENDED
COURSE OF ACTION
1. Replace lter if necessary.
2. If all recommended possible areas of misadjustment have
been checked and the problem persists, Contact your local
Lincoln Authorized Field Service Facility. 1-888-935-3878.
1. Replace the lter cartridge.
1. Remove obstructions from the outlet opening(s) and/or
connected ductwork.
2. Replace lter cartridge.
3. Install non- return valve(s) correctly.
1.Press alarm reset and investigate VFD fault issue. Note the
VFD has an LCD display that will assist troubleshooting with a
message or fault code to help determine reason for the fault.
2. If the Differential Pressure read by the sensor is higher than
your DP Alarm set point your alarm light will be on and
ashing and the unit most likely has already passed your
online cleaning set point (default of which is 1500 Pa). Filters
need to be changed if this DP reading is correct and your set
point is realistic.
Check fuses for incoming power to the drive and for the
controls power and replace if necessary.
Remove and re-apply AC line voltage to the unit after a 1
minute delay. Variable Speed Drive will reset for some faults. If
this cycle repeats locate the source of fault- checking motor,
wiring and each connection point to motor and the VSS.
Replace VFD if determined to be faulty.
After checking for proper 24VDC supply to devices. They
should each have a green power "POW" light on. Determine
normal lights seen on an operating unit if possible and
compare to the faulty controls for hints on what component
isn't operating correctly. Replace suspected component(s).
E-4
TROUBLESHOOTING