Replacing Filter Cartridges - Lincoln Electric Prism L17587-1 Operator's Manual

Table of Contents

Advertisement

PRISM
®

REPLACING FILTER CARTRIDGES

WARNING
Before opening door, unit must be off and the power
switch on the side of the control panel turned to the off
position.
Verify power has been switched off at the control panel, then
unlock door handle using the supplied hex tool or any standard
5/16" hex wrench.
a. Unclamp handles and lower lters.
FIGURE D.1
b. Remove lters.
FIGURE D.2
c. Install new lters.
FIGURE D.3
1. Slide lters out of unit through the door opening as
shown. See special note on next page for lter removal
on units with 4 lters deep.
2. If required by federal, state and/or local regulations and
guidelines, conceal lter cartridge in appropriate bag,
e.g. plastic bag.
3. Dispose of the lter cartridge in accordance with all
federal, state and/or local guidelines.
4. Clean the lter compartment with an industrial vacuum
cleaner that meets OSHA guidelines for Cr6 house-
keeping.
1. Install new lters, making sure they are pushed
against rear of unit.
2. Reclasp lter handles to lift lters to their sealed
position.
3. Re-lock door handle using the supplied hex wrench or
any standard 5/16" hex wrench.
D-4