Setup

SETTING WATER DAYS

1.
Turn the dial to the WATER DAYS position.
2.
The display will show the last program selected (A, B, or C).
Switch to another program by pressing the PRG button.
3.
The pointer at the bottom of the screen shows the currently
selected day of the week. Press + or – to select days for
watering or no water

SELECTING ODD OR EVEN DAYS TO WATER

1.
Press ► past all days of week to ODD or EVEN.
2.
Press + to select or – to cancel ODD or EVEN.

SELECTING INTERVAL WATERING

1.
Press ► past ODD and EVEN to INT.
2.
Press + or – to set interval days.
3.
Press + or – to set number of days to next watering.
NOTE: To exit interval mode, press the ► or ◄ repeatedly until
specific days of the week appear.

SEASONAL ADJUST

Changes all run times by a percentage for local conditions.
1.
Turn the dial to Seasonal Adjustment.
2.
Press + or – to change from 10% to 150% of original run times.
6
.

MANUAL SINGLE STATION

1.
Turn dial to Manual Single Station position.
2.
Press ► to select station. Use + or – to set manual run time.
3.
Turn dial to RUN position to begin immediately.

MANUAL PROGRAM

1.
Turn dial to RUN position.
2.
Press and hold ► button for three seconds.
3.
Press PRG to select program.
4.
Release button for two seconds. Program will begin.
5.
Press ► to advance to another station within the Program.

ONE-TOUCH MANUAL START AND ADVANCE

1.
Hold down the right button for two seconds.
2.
Press the PRG button to select program.
3.
Press the left or right button to select a station.
4.
Press the + or – button to change the run time.
5.
After a two-second pause, the program will begin. At any time
during manual cycle, use the left or right buttons to navigate
from station to station manually.